Festo Контроллер двигателя CMMD-AS User Manual
Page 106
6. Electrical installation
106
Festo P.BE-CMMD-AS-HW-EN 1002NH
Pin
Designation
Value
Mode = 0 – Positioning
22
DIN6
Limit switch 0
23
DIN8
Start for the positioning process (high active)
24
DOUT0
24 V100 mA
Ready for operation output (high active)
25
DOUT2
24 V100 mA
Output freely programmable – default: Start ack (low active)
Table 6.2 Pin allocation: I/O interface [X1] mode 0
Pin
Designation
Value
Mode = 1 – Jog mode
1
AGND
0 V
Screen for analogue signals
2
DIN12
24 V
Mode switch "1" = Jog mode
3
DIN10
Jog + (high active)
4
+VREF
+10 V ±4 %
Reference output for setpoint potentiometer
5
Free
6
GND24
Reference potential for digital inputs and outputs
7
DIN1
Record selection 1 (high active)
8
DIN3
Record selection 3 (high active)
9
DIN5
Controller enable/EN (high active)
(Taught positions are saved with negative edge)
10
DIN7
Limit switch 1
11
DIN9
SAMP
Digital I/O control interface:
Mode selection "0" = jog mode (high active)
Fieldbus control interface:
Sample input (high-speed input)
12
DOUT1
24 V100 mA
Output freely programmable – default motion complete (high active)
13
DOUT3
24 V100 mA
Output freely programmable – default error (low active)
14
AGND
0 V
Reference potential for the analogue signals
15
DIN13
Stop input (low active)
16
DIN11
Jog – (high active)
17
AMON0
0 ... 10 V
Analogue monitor output 0
18
+ 24 V
24 V100 mA
24 VDC feed-in carried out
19
DIN0
Record selection 0 (high active)
20
DIN2
Record selection 2 (high active)
21
DIN4
Output stage enable (high active)
22
DIN6
Limit switch 0
23
DIN8
Teach (high active)
24
DOUT0
24 V100 mA
Ready for operation output (high active)
25
DOUT2
24 V100 mA
Teach ack
Table 6.3 Pin allocation: I/O interface [X1] mode 1
Pin
Designation
Value
Mode = 2 – Route program
1
AGND
0 V
Screen for analogue signals
2
DIN12
Mode switch "0" = route program
3
DIN10
Next 1
4
+VREF
+10 V ±4 %
Reference output for setpoint potentiometer
5
Free
6
GND24
Reference potential for digital inputs and outputs
7
DIN1
Record selection 1 (high active)
8
DIN3
Stop route program