beautypg.com

Ml24xxa native commands gpib operation – Anritsu ML2430A User Manual

Page 113

background image

This message can be manipulated to program a different table using the
CFULD command.

CFUSAV

Cal factor table save

SENSOR

Syntax:

CFUSAV

Remarks:

This command saves the cal factor table currently being edited to the ap-
propriate sensor. Processing may take a couple of seconds. Any command
that can select a new sensor and/or cal factor table for changing, will not
automatically save any previous changes made. It is the users responsibil-
ity to issue a CFUSAV command.

CFUSEL

Select cal factor table

SENSOR

Syntax:

CFUSEL ,

s:

A or B

table

number:

table number or combination to use
0 = factory default table
1 to 10 = user table being used
11 to 20 = factory table + user table being used

Remarks:

Selects the cal factor table or combination of tables to be used and auto-
matically updates the sensor.

Example:

CFUSEL A,13

Selects the factory table plus user table 3 in sensor A.

CFUTBL

Number of cal factor tables in the sensor

SENSOR

Syntax:

CFUTBL

s:

A or B

Remarks:

Returns the number of cal factor tables available in the selected sensor.

CFUUSE

Number of cal factor table being used

SENSOR

Syntax:

CFUUSE

s:

A or B

6-26