beautypg.com

Allied Telesis AT-S24 User Manual

Page 79

background image

AT-S24 Version 2.01 User’s Guide

79

2. Select Enabled.

The prompts in Figure 34 are displayed.

Figure 34 Source and Destination Port Mirror Prompts

3. Select Source Port.

A window is displayed listing the ports on the switch.

4. Select the port to be monitored.

5. If you are running a web-based Omega session, return to the window

containing the prompts in Figure 34.

6. Select Destination Port.

Again, a window is displayed listing the ports on the switch.

7. Select the port where the network analyzer will be connected.

8. If you are running a web-based Omega session, return to the window

containing the prompts in Figure 34.

The prompts should now be showing both a source port and
destination port. Figure 35 is an example.

Figure 35 Example of Source and Destination Port Mirror Prompts

The two ports are now configured for port mirroring.

9. Return to the Main Menu.

10. Connect a device, such as a network analyzer, to the destination port

or use a remote monitoring program to view the mirrored traffic.