beautypg.com

Allied Telesis AT-S63 User Manual

Page 227

background image

AT-S63 Management Software Command Line Interface User’s Guide

Section II: Advanced Operations

227

Caution

After downloading an AT-S63 image file into the application block
from its file system, the switch resets and initializes its management
software. The entire process can take a minute or so to complete.
Do not interrupt the process by resetting or power cycling the switch.
Some network traffic may be lost during the process.

Example

This command downloads an AT-S63 image file already stored in the
switch’s file system into the application block, which is the area of flash
memory reserved for the active running image. This makes the file the
active image file on the switch. The name of the image file in the file
system in this example is “ats63v1 2 0.img”:

load method=local destfile=appblock srcfile=”ats63v1 2
0.img”

A confirmation prompt is displayed. Type Y for yes to transfer the file to the
application block or N for no to cancel the procedure.