Chapter 15: Building a Stack

296

Section III: Building a Stack with VCStack Plus

Figure 183. SHOW STACK Command

7. Verify the pending ID number change.

Each controller card should now have two ID numbers. The number in
the ID column is the current number of the chassis and the number in
the Pending ID column is the number you just assigned it. The new
number takes effect when you reboot the chassis later in these
instructions.

Do one of the following:

If the Pending ID column is empty or is not displaying the correct
number, repeat the procedure starting with step 3.

If the Pending ID column is displaying the correct ID number,
continue with the next step.

8. Enter the COPY RUNNING-CONFIG command to save your change:

awplus# copy running-config startup-config

9. Continue to the next procedure to set the priority number on the

chassis.

Virtual Chassis Stacking summary information

ID

Pending ID

MAC address

Priority

Status

Role

1.5

2.5

eccd.6d9e.07e1

128

Ready

Active CFC

1.6

2.6

eccd.6d9e.0145

128

Ready

Backup Member

Current ID

Number

Pending ID

Number