beautypg.com

Figure 151: show version command – Allied Telesis AT-SBx81CFC960 User Manual

Page 213

background image

SwitchBlade x8106 Chassis Switch and AT-SBx81CFC960 Card Installation Guide

Section II: Installing the Chassis

213

3. Configure the VT-100 terminal or terminal emulation program as

follows:

Baud rate: 115,200 bps

Data bits: 8

Parity: None

Stop bits: 1

Flow controller: None

Note

The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.

4. Press Enter. You are prompted for a user name and password.

5. Enter the default user name and password. They are “manager” and

“friend” (without the quotes), respectively

Note

User names and passwords are case sensitive.

The local management session starts and the command line interface
(CLI) prompt is displayed.

Entering the

AlliedWare Plus

Operating System

Commands

To confirm the operations of the chassis with the commands in the
AlliedWare Plus Operating System, perform the following procedure:

1. Enter the SHOW VERSION command in the User Exec or Privileged

Exec mode to display the software version number of the AlliedWare
Plus Operating System on the controller card, as shown in Figure 151.

Figure 151. SHOW VERSION Command

awplus# show version

AlliedWare Plus (TM) 5.4.4

Build name : SBx81CFC960-5.4.4.rel
Build date : Wed Dec 15 12:13:19 NZDR 2013
Build type : RELEASE

NEW-SNMP SNMP agent software
(c) 1996, 1998-2000 The Regents of the University of California.

All rights reserved;

.
.
.

Software Version

Number

This manual is related to the following products: