1.8.6 SET INITIAL BAUD
Table 1.8-10 shows the option codes available
for setting the initial baud rate. Setting the initial
baud rate forces the CR10X to try the selected
baud rate first when connecting with a device.
TABLE 1.8-9. Set Initial Baud Rate / Set
RS232 Power
Key
Entry
Display
Comments
*D
13:00
Enter Command
12A
12:00
Connect Baud Rate
Enter Baud Rate Code X
(Table 1.8-11).
TABLE 1.8-10. Baud Rate Codes
X = 0
300 Baud
X = 1
1200 Baud
X = 2
9600 Baud
X = 3
76.8 K Baud
1.8.7 SET PROGRAM COMPILE OPTION
Table 1.8-12 shows the option codes available
for setting the program compile option. This
setting will affect the program compile when the
program is downloaded from the PC or a
SM192/716 Storage Module. It also affects
compiling with *B and the arcane *D7
command. Keyboard or Remote Keyboard
compiling with *6 and *0 is not affected by this
setting. If a .DLD file has this setting, it will
affect the compile operation AFTER the .DLD
file is downloaded.
TABLE 1.8-11. Set Program Compile Option
Key
Entry
Display
Comments
*D
13:00
Enter Command
13A
13:00
Compile Option
1A
13:01
Sets Compile like *6
TABLE 1.8-12. Compile Option Codes
0
Compile like *0 (See Section 1.4)
1
Compile like *6 (See Section 1.3)
2
Do not clear intermediate storage