beautypg.com

Campbell Scientific CR10X Measurement and Control System User Manual

Page 122

background image

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES

8-14

20:

Covariance/Correlation (P62)
1:

5

No. of Input Locations

2:

5

No. of Means

3:

5

No. of Variances

4:

0

No. of Std. Dev.

5:

4

No. of Covariance

6:

2

No. of Correlations

7:

300

Samples per Average

8:

1

First Sample Loc [ W1 ]

9:

20

Loc [ MEAN_W1 ]

21:

Covariance/Correlation (P62)
1:

5

No. of Input Locations

2:

5

No. of Means

3:

5

No. of Variances

4:

0

No. of Std. Dev.

5:

9

No. of Covariance

6:

2

No. of Correlations

7:

300

Samples per Average

8:

11

First Sample Loc [ W2_i ]

9:

36

Loc [ mean_W2 ]

22:

Real Time (P77)
1: 0110

Day,Hour/Minute

23:

Sample (P70)
1:

35

Reps

2:

20

Loc [ mean_W1 ]

TABLE 8.10-4. Thirty Minute Output From Example

01 119

02 DAY

03 HRMIN

04 M(W1)

05 M(U1)

06 M(V1)

07 M(Ta1)

08 M(e1)

09 V(W1)

10 V(U1)

11 V(V1)

12 V(Ta1)

13 V(e1)

14 CV(W1,U1) 15 CV(W1,V1) 16 CV(W1,Ta1)

17 CV(W1,e1) 18 CR(W1,U1)

19 CR(W1,V1) 20 M(W2)

21 M(U2)

22 M(V2)

23 M(Ta2)

24 M(e2)

25 V(W2)

26 V(U2)

27 V(V2)

28 V(Ta2)

29 V(e2)

30 CV(W2,U2) 31 CV(W2,V2) 32 CV(W2,Ta2)

33 CV(W2,e2) 34 CV(U2,V2)

35 CV(U2,Ta2) 36 CV(U2,e2) 37 CV(V2,Ta2) 38 CV(V2,e2)