Campbell Scientific CR10X Measurement and Control System User Manual
Page 316

TD ADDENDUM—SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
AD-8-4
FIGURE 8.3-1. AM416 Wiring Diagram For Thermocouple and Soil Moisture Block Measurements
EXAMPLE PROGRAM MULTIPLEXING
THERMOCOUPLES AND SOIL MOISTURE
BLOCK
*
1
Table 1 Programs
01:
600
Sec. Execution Interval
01:
P11
Temp 107 Probe
01:
1
Rep
02:
4
IN Chan
03:
1
Excite all reps w/EXchan 1
04:
1
Loc [:REF_TEMP ]
05:
1
Mult
06:
0
Offset
02:
P86
Do
01:
41
Set high Port 1
03:
P87
Beginning of Loop
01:
0
Delay
02:
16
Loop Count
04:
P86
Do
01:
72
Pulse Port 2
05:
P14
Thermocouple Temp (DIFF)
01:
1
Rep
02:
21
2.5 mV 60 Hz rejection
Range
03:
1
IN Chan
04:
1
Type T (Copper-Constantan)
05:
1
Ref Temp Loc REF_TEMP
06:
2--
Loc [:TC_TEMP_1]
07:
1
Mult
08:
0
Offset
06:
P5
AC Half Bridge
01:
1
Rep
02:
14
250 mV fast Range
03:
3
IN Chan
04:
1
Excite all reps w/EXchan 1
05:
250
mV Excitation
06:
18--
Loc [:SOIL_M_1 ]
07:
1
Mult
08:
0
Offset
07:
P95
End
08:
P86
Do
01:
51
Set low Port 1
09:
P59
BR Transform Rf[X/(1-X)]
01:
16
Reps
02:
18
Loc [:SOIL_M_1 ]
03:
.1
Multiplier (Rf)
10:
P84
Data Table
01:
0
Seconds into interval
02: 3600
Seconds interval
03:
0
Records (0=auto; -=redirect)
11:
P71
Average
01:
33
Reps
02:
1
Loc REF_TEMP
12:
P
End Table 1
CR10X
- 014A Met One Wind Speed Sensor (36 pages)
- 020C Wind Direction Sensor (26 pages)
- 024A-L Met One Wind Direction Sensor (30 pages)
- 03001-L R.M. Young Wind Sentry Set (34 pages)
- 03002, 03101, and 03301 R. M. Young Wind Sentry Sensors (40 pages)
- 034A-L WindSet (16 pages)
- 034B-L Met One Windset (34 pages)
- 036, 038 Spark Gapped Junction Box (6 pages)
- 05103, 05103-45, 05106, and 05305 R. M. Young Wind Monitors (30 pages)
- 083E Relative Humidity and Temperature Sensor (22 pages)
- 0871LH1 Freezing Rain Sensor (31 pages)
- 092 Barometric Pressure Sensor (24 pages)
- 10164-L Water Sampler Control Cable for use with Isco and Sigma Autosamplers (18 pages)
- 107-L Temperature Probe (28 pages)
- 108-LC Temperature Probe for MetData1 (12 pages)
- 108-L Temperature Probe (30 pages)
- 109-L Temperature Probe (30 pages)
- 109SS Temperature Probe (32 pages)
- 110PV Surface Temperature Probe (32 pages)
- 21108 RF450 Demo Kit (14 pages)
- 223-L Delmhorst Cylindrical Soil Moisture Block (28 pages)
- 227-L Delmhorst Cylindrical Soil Moisture Block (24 pages)
- 229 Water Matric Potential Sensor and CE4/CE8 (34 pages)
- 237-L Leaf Wetness Sensor (14 pages)
- 247-L Conductivity and Temperature (18 pages)
- 253-L and 257-L (Watermark 200) Soil Matric Potential Sensors (36 pages)
- 25458 DIN-Rail Terminal Kit (10 pages)
- 255-100 Novalynx Analog Output Evaporation Gauge (16 pages)
- 260-953 Alter-Type Wind Screen for Tipping Bucket Rain Gages (14 pages)
- 27106T Gill Propeller Anemometer (18 pages)
- 30066 Battery Terminal Bus (1 page)
- 380, 385, 380M, 385M Met One Rain Gages (22 pages)
- 3WHB10K 3-Wire Half-Bridge Terminal Input Module (14 pages)
- 43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield (40 pages)
- 4386 Battery Terminal Bus (1 page)
- 4WFB120, 4WFB350, 4WFB1K 4-Wire Full Bridge Terminal Input Module (22 pages)
- 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (46 pages)
- 4WPB100, 4WPB1K PRT Terminal Input Modules (16 pages)
- 52202 Electrically Heated Rain and Snow Gage (16 pages)
- 9522B Iridium Satellite Modem and COM9522B Interface Modem (46 pages)
- A100LK Anemometer (18 pages)
- A150 Desiccated Case (12 pages)
- A21REL-12 Relay Driver (10 pages)
- A6REL-12 Relay Driver (12 pages)
- AL200 ALERT2 Encoder, Modulator, and Sensor Interface (44 pages)