1336-series drive control logic chart, Table 53 – Alliance Laundry Systems 160 User Manual
Page 95

Allen-Bradley 1336-Series AC Drives
93
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1336-Series Drive Control Logic Chart
Cabinet Freestanding
WE-6 Control
H – Control Voltage High (approximately 5 V DC)
L – Control Voltage Low (less than 1 V DC)
0 = No Signal Received
1 = Signal Received
SW2
SW1
SW3
Rev
Stop
Fwd
Input Status - Parameter #55
DC Volt Meter Red Probe Terminal Location
27
28
26
22
20
19
DC Volt Meter Black Probe Terminal Location
29
29
29
29
29
29
Action
Frequency
Preset
Parameter
Terminal
#27
(SW2)
Terminal
#28
(SW1)
Terminal
#26
(SW3)
Terminal
#22
(STR)
Terminal
#20
(Stop)
Terminal
#19
(STF)
SW
2
SW
1
SW
3
Auxi
li
ar
y
Re
v (
S
TR)
Not Used
St
o
p
F
w
d (
S
TF
)
Idle
N/A
H
H
H
H
L/H
H
0
0
0
1
0
0
0/1
0
Half-Wash Speed Forward
73
H
H
L
H
L
L
0
0
1
1
0
0
1
1
Half-Wash Speed Reverse
73
H
H
L
L
L
H
0
0
1
1
1
0
1
0
Wash Speed Forward
28
L
H
H
H
L
L
1
0
0
1
0
0
1
1
Wash Speed Reverse
28
L
H
H
L
L
H
1
0
0
1
1
0
1
0
Distribution Speed
27
H
L
H
H
L
L
0
1
0
1
0
0
1
1
Medium Extract
75
L
H
L
H
L
L
1
0
1
1
0
0
1
1
High 1 Extract
74
H
L
L
H
L
L
0
1
1
1
0
0
1
1
High 2 Extract
29
L
L
H
H
L
L
1
1
0
1
0
0
1
1
High 3 Extract
76
L
L
L
H
L
L
1
1
1
1
0
0
1
1
Table 53