PowerFlex 40 and 400 Drive Control Logic

F232120

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

PowerFlex 40 Drive Control Logic Chart

Cabinet Hardmount

“A” control, “B” control, “V” Control and EDC/Netmaster Control

H – Signal Voltage High (approximately 24V DC)
L – Signal Voltage Low (less than 1V DC)

0 = No signal received

1 = Signal received

Digital

In 3

Digital

In 2

Digital

In 1

Stop

Rev

Fwd

Digital Input

Status – Parameter

d014

Control Input

Status – Parameter

d013

DC Volt Meter Red Probe Terminal Location

07

06

05

01

03

02

DC Volt Meter Black Probe Terminal Location

04

04

04

04

04

04

Action

Frequency

Preset

Parameter #

Terminal

#07

(SW3)

Terminal

#06

(SW2)

Terminal

#05

(SW1)

Terminal

#01

(Stop)

Terminal

#03

(STR)

Terminal

#02

(STF)

*Di

g

it

a

l I

n

4

Digi

ta

l In 3

(SW3)

Digi

ta

l In 2

(SW2)

Digi

ta

l In 1

(SW1)

DB T

rans

On

St

o

p

Rev (STR)

Fw

d (STF)

Idle

N/A

H

H

H

L/H

H

H

0

0

0

0

0

0/1

0

0

1/2 Wash Speed Forward

71

H

H

L

L

H

L

*1

0

0

1

0

1

0

1

1/2 Wash Speed Reverse

71

H

H

L

L

L

H

0

0

0

1

0

1

1

0

Wash Speed Forward

72

H

L

H

L

H

L

*1

0

1

0

0

1

0

1

Wash Speed Reverse

72

H

L

H

L

L

H

0

0

1

0

0

1

1

0

Distribution Speed

74

L

H

H

L

H

L

*1

1

0

0

0

1

0

1

Spin 1

73

H

L

L

L

H

L

*1

0

1

1

0

1

0

1

Spin 2

76

L

L

H

L

H

L

*1

1

1

0

0

1

0

1

Spin 3

75

L

H

L

L

H

L

*1

1

0

1

0

1

0

1

*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.

Cabinet Hardmount

Galaxy control, Quantum control and UniMac Software Control

H – Signal Voltage High (approximately 24V DC)
L – Signal Voltage Low (less than 1V DC)

0 = No signal received

1 = Signal received

Digital

In 3

Digital

In 2

Digital

In 1

Stop

Rev

Fwd

Digital Input

Status – Parameter

d014

Control Input

Status – Parameter

d013

DC Volt Meter Red Probe Terminal Location

07

06

05

01

03

02

DC Volt Meter Black Probe Terminal Location

04

04

04

04

04

04

Action

Frequency

Preset

Parameter #

Terminal

#07

(SW3)

Terminal

#06

(SW2)

Terminal

#05

(SW1)

Terminal

#01

(Stop)

Terminal

#03

(STR)

Terminal

#02

(STF)

*D

ig

it

a

l In

4

D

igit

a

l In

3

D

igit

a

l In

2

D

igit

a

l In

1

DB T

rans

On

St

o

p

Re

v

Fw

d

Idle

N/A

H

H

H

L/ H

H

H

0

0

0

0

0

0/1

0

0

Reduced Wash speed (ccw)

70

H

H

H

L

L

H

0

0

0

0

0

1

1

0

Reduced Wash Speed (cw)

70

H

H

H

L

H

L

0

0

0

0

0

1

0

1

Wash Speed (ccw)

72

H

L

H

L

L

H

0

0

1

0

0

1

1

0

Wash Speed (cw)

72

H

L

H

L

H

L

0

0

1

0

0

1

0

1

Distribution Speed 1 (ccw)

71

H

H

L

L

L

H

0

0

0

1

0

1

1

0

Extract Speed 1 (ccw)

76

L

L

H

L

L

H

0

1

1

0

0

1

1

0

Extract Speed 2 (ccw)

75

L

H

L

L

L

H

0

1

0

1

0

1

1

0

Extract Speed 3 (ccw)

73

H

L

L

L

L

H

0

0

1

1

0

1

1

0

Extract Speed 4 (ccw)

77

L

L

L

L

L

H

0

1

1

1

0

1

1

0

Extract Speed 5 (ccw)

74

L

H

H

L

L

H

0

1

0

0

0

1

1

0

Table 8