Bles 8, Powerflex 40 drive control logic chart, Table 8 – Alliance Laundry Systems 160 User Manual
Page 16

PowerFlex 40 and 400 Drive Control Logic
F232120
14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
PowerFlex 40 Drive Control Logic Chart
Cabinet Hardmount
“A” control, “B” control, “V” Control and EDC/Netmaster Control
H – Signal Voltage High (approximately 24V DC)
L – Signal Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
Digital
In 3
Digital
In 2
Digital
In 1
Stop
Rev
Fwd
Digital Input
Status – Parameter
d014
Control Input
Status – Parameter
d013
DC Volt Meter Red Probe Terminal Location
07
06
05
01
03
02
DC Volt Meter Black Probe Terminal Location
04
04
04
04
04
04
Action
Frequency
Preset
Parameter #
Terminal
#07
(SW3)
Terminal
#06
(SW2)
Terminal
#05
(SW1)
Terminal
#01
(Stop)
Terminal
#03
(STR)
Terminal
#02
(STF)
*Di
g
it
a
l I
n
4
Digi
ta
l In 3
(SW3)
Digi
ta
l In 2
(SW2)
Digi
ta
l In 1
(SW1)
DB T
rans
On
St
o
p
Rev (STR)
Fw
d (STF)
Idle
N/A
H
H
H
L/H
H
H
0
0
0
0
0
0/1
0
0
1/2 Wash Speed Forward
71
H
H
L
L
H
L
*1
0
0
1
0
1
0
1
1/2 Wash Speed Reverse
71
H
H
L
L
L
H
0
0
0
1
0
1
1
0
Wash Speed Forward
72
H
L
H
L
H
L
*1
0
1
0
0
1
0
1
Wash Speed Reverse
72
H
L
H
L
L
H
0
0
1
0
0
1
1
0
Distribution Speed
74
L
H
H
L
H
L
*1
1
0
0
0
1
0
1
Spin 1
73
H
L
L
L
H
L
*1
0
1
1
0
1
0
1
Spin 2
76
L
L
H
L
H
L
*1
1
1
0
0
1
0
1
Spin 3
75
L
H
L
L
H
L
*1
1
0
1
0
1
0
1
*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.
Cabinet Hardmount
Galaxy control, Quantum control and UniMac Software Control
H – Signal Voltage High (approximately 24V DC)
L – Signal Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
Digital
In 3
Digital
In 2
Digital
In 1
Stop
Rev
Fwd
Digital Input
Status – Parameter
d014
Control Input
Status – Parameter
d013
DC Volt Meter Red Probe Terminal Location
07
06
05
01
03
02
DC Volt Meter Black Probe Terminal Location
04
04
04
04
04
04
Action
Frequency
Preset
Parameter #
Terminal
#07
(SW3)
Terminal
#06
(SW2)
Terminal
#05
(SW1)
Terminal
#01
(Stop)
Terminal
#03
(STR)
Terminal
#02
(STF)
*D
ig
it
a
l In
4
D
igit
a
l In
3
D
igit
a
l In
2
D
igit
a
l In
1
DB T
rans
On
St
o
p
Re
v
Fw
d
Idle
N/A
H
H
H
L/ H
H
H
0
0
0
0
0
0/1
0
0
Reduced Wash speed (ccw)
70
H
H
H
L
L
H
0
0
0
0
0
1
1
0
Reduced Wash Speed (cw)
70
H
H
H
L
H
L
0
0
0
0
0
1
0
1
Wash Speed (ccw)
72
H
L
H
L
L
H
0
0
1
0
0
1
1
0
Wash Speed (cw)
72
H
L
H
L
H
L
0
0
1
0
0
1
0
1
Distribution Speed 1 (ccw)
71
H
H
L
L
L
H
0
0
0
1
0
1
1
0
Extract Speed 1 (ccw)
76
L
L
H
L
L
H
0
1
1
0
0
1
1
0
Extract Speed 2 (ccw)
75
L
H
L
L
L
H
0
1
0
1
0
1
1
0
Extract Speed 3 (ccw)
73
H
L
L
L
L
H
0
0
1
1
0
1
1
0
Extract Speed 4 (ccw)
77
L
L
L
L
L
H
0
1
1
1
0
1
1
0
Extract Speed 5 (ccw)
74
L
H
H
L
L
H
0
1
0
0
0
1
1
0
Table 8