beautypg.com

Figure 10, Powerflex 40 control terminal block designations, Control input/output terminal block – Alliance Laundry Systems 160 User Manual

Page 14: 26 awg) table 7

background image

PowerFlex 40 and 400 Drive Control Logic

F232120

12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

PowerFlex 40 Control Terminal Block
Designations

Figure 10

Control Input/Output Terminal Block

PHM780N

+

-

18

17

16

15

14

13

12

11

19

19

09

18

08

17

07

16

06

15

05

14

04

13

03

12

02

11

01

R3

R3

ENBL

RS485 Shield

Opto Output 2

Bal Output

Analog Output

4-20mA Input

Analog Common

0-10V ( or ± 10V) Input

+ 10V DC

+ 24V DC

Bal Common

Digital Input 4

Digital Input 3

Digital Input 2

Digital Input 1

Digital Common

REV

FWD

Stop

SNK

SRC

+10V

+24V

0-10V

0/4-20mA

30V DC
50mA
Non-inductive

Relay N.O.

Relay Common

Relay N.C.

Pot must be
1-10k ohm
1 Watt Min.

Common

24V

Enable
Jumper

Control Wiring Block Diagram

Enable

Jumper

RS485

(DSI)

0-10V

Analog Output Select

0-20mA

SNK

SRC

R2

R1

R2

R1

08

07

06

05

04

03

02

01

09

Typical

SNK Wiring

Torque

0.5-0.8 N-m (4.4-7.0 lb-in)

Max Wire Size

1.3 mm

2

(16 AWG)

Min Wire Size

0.13 mm

2

(26 AWG)

Table 7

This manual is related to the following products: