PowerFlex 40 and 400 Drive Control Logic
F232120
24
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
PowerFlex Drive Parameters
PowerFlex 40
Parameter
Group and
Number
PowerFlex 400 Parameter Group
and Number
Parameter
Description
Function
d001
b001
Output
Frequency
Displays instantaneous output frequency
(in Hz).
d002
b002
Command
Frequency
Displays command output frequency (in
Hz).
d003
b003
Output Current
Displays output current (in Amps).
d004
b004
Output Voltage
Displays output voltage (in VAC).
d005
b005
DC Bus Voltage
Displays DC Bus capacitor voltage (in
VDC).
d006
b006
Drive Status
Read from left to right, the four bits
indicate the drive's condition
(decelerating, accelerating, forward and
running). “0” = false and “1” = true
d007
d307
Fault 1 Code
Memory location for the most recent
fault. Refer to Table 20 for a list of most
fault codes. Repetitive faults are stored
only once.
d008
d308
Fault 2 Code
Memory location for the 2nd most recent
fault. Refer to Table 20 for a list of most
fault codes. Repetitive faults are stored
only once.
d009
d309
Fault 3 Code
Memory location for the 3rd most recent
fault. Refer to Table 20 for a list of most
fault codes. Repetitive faults are stored
only once.
d010
b008
Process Display
Not applicable to Alliance Laundry
Systems’ equipment. Refer to the
manual supplied with the PowerFlex
drive for detailed information.
d012
d301
Control Source
Read from left to right, the digits
indicate the active source of the Speed
Reference (P038) and Start Source
(P036) command.
d013
d302
Control Input
Status
Refer to Table 8 through Table 14 for
Control Status Input diagnostics.
d014
d302
Digital Input
Status
Refer to Table 8 through Table 14 for
Digital Input Status diagnostics.
d015
d303
Communication
Status
Not applicable to Alliance Laundry
Systems' equipment. Refer to the manual
supplied with the PowerFlex drive for
detailed information.
Table 16 (continued)