beautypg.com

Electrical interference, Caution, Electrical interference emi – Alliance Laundry Systems 160 User Manual

Page 87

background image

Allen-Bradley 1336-Series AC Drives

85

F232120

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Electrical Interference

EMI

Careful attention must be given to the arrangement of
power and ground connections to the drive to avoid
interference with nearby sensitive equipment. Be sure
to replace all ground connections to their appropriate
locations.

RFI

Drives can be installed with an RFI filter, which
controls high-frequency conducted emissions into the
main supply lines.

Where it is essential that very low emission levels
must be achieved or if conformity with standards is
required, the optional RFI filter may be present.
Figure 47 displays an electrical schematic for various
RFI configurations. Table 47 shows associated RFI
filter part numbers.

Figure 47

CAUTION

ELECTRIC SHOCK HAZARD! Service and

maintenance to be performed only by an
authorized technician. Disconnect power
before opening any access panels.

W661

U166ME3A

L1

TO AC DRIVE UNIT Ð
GREEN-YELLOW WIRE MUST CONNECT TO
AC DRIVE GROUND TERMINAL.
BLACK WIRES WILL CONNECT TO AC DRIVE
INPUT TERMINALS "R", "S" & "T".
BLACK WIRES ARE NOT LABELED AND THEIR
RESPECTIVE TERMINATION IN AC DRIVE IS
NOT OF IMPORTANCE.

L2

ALLEN-BRADLEY

RFI

FILTER

L3

LINE

LOAD

PROVEN EARTH GROUND

WASHING

MACHINE

GROUNDING

TERMINAL

THREE PHASE MACHINES

INPUT

POWER

1 2

3

2

3

L1

TO AC DRIVE UNIT Ð
GREEN-YELLOW WIRE MUST CONNECT TO
AC DRIVE GROUND TERMINAL.
BLACK WIRES WILL CONNECT TO AC DRIVE
INPUT TERMINALS "R", "S" & "T".
BLACK WIRES ARE NOT LABELED AND THEIR
RESPECTIVE TERMINATION IN AC DRIVE IS
NOT OF IMPORTANCE.

L2

ALLEN-BRADLEY

RFI

FILTER

LINE

LOAD

PROVEN EARTH GROUND

WASHING

MACHINE

GROUNDING

TERMINAL

SINGLE PHASE MACHINES

INPUT

POWER

1 2

3

2

3

U166ME3A

RFI Filter Part Number Information

Drive P/N

Drive Catalog

Machine Voltage

Filter P/N

370838

1336-AQF50

200-240V/1 Phase

Not Available

370838

1336-AQF50

200-240V/3 Phase

330274

370835

1336-BRF50

380-480V/3 Phase

330273

370837

1336-AQF100

200-240V/3 Phase

Not Available

370834

1336-BRF100

380-480V/3 Phase

330274

370828

1336-AO15

200-240V/3 Phase

330268

370825

1336-BO25

380-480V/3 Phase

330268

Table 47

This manual is related to the following products: