160 Series Drive Control Logic Chart

The following truth table (Tables 26 - 30) designates
the preset speed selection based on the inputs to the
control terminals. A disconnected control terminal will
seek the high signal voltage condition (greater than
10V DC).

To activate a control input (i.e., SW1, SW2, etc.), the
terminal is connected to a common terminal (TB3-3 or
TB3-7) to lower the signal voltage to a low condition
(less than 1 Volt DC).

Pocket Hardmount

V Control and A control

H – Control Voltage High (greater than 10V DC)
L – Control Voltage Low (less than 1V DC)

0 = No signal received

1 = Signal received

SW3

SW2

SW1

STF

Stop

STR

Preset Status –

Parameter 15

Input Status –

Parameter 12

DC Volt Meter Red Probe Terminal Location

4

2

1

6

8

5

DC Volt Meter Black Probe Terminal Location

3

3

3

3

3

3

Action

Frequency

Preset

Parameter #

Terminal

#4

(SW3)

Terminal

#2

(SW2)

Terminal

#1

(SW1)

Terminal

#6

(STF)

Terminal

#8

(Stop)

Terminal

#5

(STR)

Not Us

ed

SW

3

SW

2

SW

1

Not Us

ed

ST

F

St

o

p

STR

Idle

N/A

H

H

H

H

L/H

H

0

0

0

0

0

0

0/1

0

1/2 Wash Speed Forward

62

H

H

L

L

L

H

0

0

0

1

0

1

1

0

1/2 Wash Speed Reverse

62

H

H

L

H

L

L

0

0

0

1

0

0

1

1

Wash Speed Forward

63

H

L

H

L

L

H

0

0

1

0

0

1

1

0

Wash Speed Reverse

63

H

L

H

H

L

L

0

0

1

0

0

0

1

1

Distribution Speed

65

L

H

H

L

L

H

0

1

0

0

0

1

1

0

Spin 1

64

H

L

L

L

L

H

0

0

1

1

0

1

1

0

Spin 2

67

L

L

H

L

L

H

0

1

1

0

0

1

1

0

Spin 3

66

L

H

L

L

L

H

0

1

0

1

0

1

1

0

Pocket Hardmount

WE-6 Control - Design 5 and Earlier

H – Control Voltage High (greater than 10V DC)
L – Control Voltage Low (less than 1V DC)

0 = No signal received

1 = Signal received

SW3

SW2

SW1

STF

Stop

STR

Preset Status –

Parameter 15

Input Status –

Parameter 12

DC Volt Meter Red Probe Terminal Location

4

2

1

6

8

5

DC Volt Meter Black Probe Terminal Location

3

3

3

3

3

3

Action

Frequency

Preset

Parameter #

Terminal

#4

(SW3)

Terminal

#2

(SW2)

Terminal

#1

(SW1)

Terminal

#6

(STF)

Terminal

#8

(Stop)

Terminal

#5

(STR)

Not U

s

ed

SW3

SW2

SW1

Not U

s

ed

STF

St

o

p

STR

Idle

N/A

H

H

H

H

L/H

H

0

0

0

0

0

0

0/1

0

1/2 Wash Speed Forward

65

L

H

H

L

L

H

0

1

0

0

0

1

1

0

1/2 Wash Speed Reverse

65

L

H

H

H

L

L

0

1

0

0

0

0

1

1

Wash Speed Forward

63

H

L

H

L

L

H

0

0

1

0

0

1

1

0

Wash Speed Reverse

63

H

L

H

H

L

L

0

0

1

0

0

0

1

1

Distribution Speed

62

H

H

L

L

L

H

0

0

0

1

0

1

1

0

Medium Extract/Spray Rinse

67

L

L

H

L

L

H

0

1

1

0

0

1

1

0

High 1 Extract

66

L

H

L

L

L

H

0

1

0

1

0

1

1

0

High 2 Extract

64

H

L

L

L

L

H

0

0

1

1

0

1

1

0

High 3 Extract

68

L

L

L

L

L

H

0

1

1

1

0

1

1

0

Table 26