beautypg.com

160 series drive control logic chart, Table 29 – Alliance Laundry Systems 160 User Manual

Page 47

background image

Allen-Bradley 160-Series AC Drives

45

F232120

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

160 Series Drive Control Logic Chart

Cabinet Freestanding - 18 lb. and 25 lb.

P Control, V control and EDC/Netmaster control

H – Control Voltage High (greater than 10V DC)
L – Control Voltage Low (less than 1V DC)

0 = No signal received

1 = Signal received

SW3

SW2

SW1

STF

Stop

STR

Preset Status –

Parameter 15

Input Status –

Parameter 12

DC Volt Meter Red Probe Terminal Location

4

2

1

6

8

5

DC Volt Meter Black Probe Terminal Location

3

3

3

3

3

3

Action

Frequency

Preset

Parameter #

Terminal

#4

(SW3)

Terminal

#2

(SW2)

Terminal

#1

(SW1)

Terminal

#6

(STF)

Terminal

#8

(Stop)

Terminal

#5

(STR)

Not Used

SW3

SW2

SW1

Not Used

STF

St

o

p

ST

R

Idle

N/A

H

H

H

H

L/H

H

0

0

0

0

0

0

0/1

0

1/2 Wash Speed Forward

62

H

H

L

L

L

H

0

0

0

1

0

1

1

0

1/2 Wash Speed Reverse

62

H

H

L

H

L

L

0

0

0

1

0

0

1

1

Wash Speed Forward

63

H

L

H

L

L

H

0

0

1

0

0

1

1

0

Wash Speed Reverse

63

H

L

H

H

L

L

0

0

1

0

0

0

1

1

Distribution Speed

65

L

H

H

L

L

H

0

1

0

0

0

1

1

0

Spin 1

64

H

L

L

L

L

H

0

0

1

1

0

1

1

0

Spin 2

67

L

L

H

L

L

H

0

1

1

0

0

1

1

0

Spin 3

66

L

H

L

L

L

H

0

1

0

1

0

1

1

0

Cabinet Freestanding

WE-6 Control

H – Control Voltage High (greater than 10V DC)
L – Control Voltage Low (less than 1V DC)

0 = No signal received

1 = Signal received

SW3

SW2

SW1

STF

Stop

STR

Preset Status –

Parameter 15

Input Status –

Parameter 12

DC Volt Meter Red Probe Terminal Location

4

2

1

6

8

5

DC Volt Meter Black Probe Terminal Location

3

3

3

3

3

3

Action

Frequency

Preset

Parameter #

Terminal

#4

(SW3)

Terminal

#2

(SW2)

Terminal

#1

(SW1)

Terminal

#6

(STF)

Terminal

#8

(Stop)

Terminal

#5

(STR)

No

t Use

d

SW

3

SW

2

SW

1

No

t Use

d

STF

St

o

p

STR

Idle

N/A

H

H

H

H

L/H

H

0

0

0

0

0

0

0/1

0

1/2 Wash Speed Forward

65

L

H

H

L

L

H

0

1

0

0

0

1

1

0

1/2 Wash Speed Reverse

65

L

H

H

H

L

L

0

1

0

0

0

0

1

1

Wash Speed Forward

63

H

L

H

L

L

H

0

0

1

0

0

1

1

0

Wash Speed Reverse

63

H

L

H

H

L

L

0

0

1

0

0

0

1

1

Distribution Speed

62

H

H

L

L

L

H

0

0

0

1

0

1

1

0

Medium Extract

67

L

L

H

L

L

H

0

1

1

0

0

1

1

0

High 1 Extract

66

L

H

L

L

L

H

0

1

0

1

0

1

1

0

High 2 Extract

64

H

L

L

L

L

H

0

0

1

1

0

1

1

0

High 3 Extract

68

L

L

L

L

L

H

0

1

1

1

0

1

1

0

Table 29

This manual is related to the following products: