beautypg.com

Ac drive diagnostics/parameter viewing, Human interface module (him or parameter unit), Caution – Alliance Laundry Systems 160 User Manual

Page 100: Warning

background image

Allen-Bradley 1336-Series AC Drives

F232120

98

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

AC Drive Diagnostics/Parameter
Viewing

Human Interface Module (HIM or
Parameter Unit)

Installation/Removal

The following are instructions for installing/removing
the Human Interface Module (P/N F370597) on the
drive for parameter viewing and basic troubleshooting.
The parameter unit (F370597) and instructions
(F232120) are included in the Parameter Kit (P/N
F744501).

Installing the HIM

1. Remove power from machine at main

disconnect. Delay approximately three minutes.

2. Remove the front cover.

3. Slide blank panel cover toward base of drive and

remove it. Place top edge of HIM approximately
1/2 inch from top edge of the cover. Push inward
on bottom of HIM and slide HIM up (toward the
top of the drive) into position.

Removing the HIM

1. Remove power from machine at main

disconnect. Delay approximately three minutes.

2. Remove front cover.

3. Press retaining lever located directly beneath

HIM. Slide HIM downward and remove it from
drive.

4. Replace front cover.

External HIM Connection

The HIM unit can be installed using an adapter cable
(P/N P370716). This method of attaching the HIM
uses an external connector shown in Figure 54. The
HIM unit operates in the same manner in this
configuration.

NOTE: If the HIM is removed while the drive is
powered, a communication fault (Serial Fault #10)
will occur and the drive will be disabled. Cycle
power to the drive to reset the fault condition.

Figure 54

CAUTION

Users are prohibited from changing
parameter values unless specifically
instructed by the washer-extractor
manufacturer. Modification to parameter
values may present potential harmful
operating conditions for both hardware and
personnel.

W673

WARNING

To reduce risk of electric shock, severe
injury or death, allow machine power to
remain off for three minutes minimum prior
to working in and around AC drive. Proceed
with caution.

W662