Specifications

94

900-0009-01-00 Rev

C

Default Settings and Ranges

Table 4

FLEXmax Settings

Mode

Menu Item

Setting

Charger

Current Limit (FLEXmax 80)

Default 80 Adc

Range: 5 to 80 Adc

Current Limit (FLEXmax 60)

Default 60 Adc

Range: 5 to 60 Adc

Absorbing

Default 14.4 Vdc

Range: Float setting to

80 Vdc

Float

Default 13.8 Vdc

Range: 12.0 Vdc to

Absorbing setting





















Aux


















Vent Fan

Default

Volts

Default 14.4 Vdc

Range: 10. 0 to 80.0 Vdc

PV Trigger

Default

Hold Time Sec

Default 01.1 second

Range: 0 to 25 seconds

PV VOLTS

Default 140 Vdc

Range: 20 to150 Vdc

ERROR OUTPUT

Default

ERROR LOW BAT

VOLTS

Default 11.5 Vdc

Range: 10 to 80 Vdc

Night Light

Default

ON Hysteresis Time
(Minutes)

Default 001 minute

Range: 001 to 255 min.

On Time (Hours)

Default 04 hours

Range: 00 to 23 hours

Threshold Voltage

Default 010 Vdc

Range: 005 to 150 Vdc

Float

Default

Diversion:Relay

Default

Hold Time (Seconds)

Default 0.1 second

Range: 0.0 to 25 sec.

Delay Time (Seconds)

Default 0.0 seconds

Range: 0.0 to 24 sec.

Absorb-Float-EQ
Relative Volts

Default 0.0 Vdc

Range: 0.0 to 5.0 Vdc

HYST

Default 00.2 Vdc

Range: 0.0 to12.0 Vdc

Diversion:Solid St

Default

Hold Time (Seconds)

Default 0.1 second

Range: 0.0 to 25 sec.

Delay Time (Seconds)

Default 00 seconds

Range: 00 to 24 sec.

Absorb-Float-EQ
Relative Volts

Default 0.0 Vdc

Range: 0.0 to 5.0 Vdc

HYST

Default 00.2 Vdc

Range: 0.0 to12.0 Vdc

Mode

Menu Item

Setting



Aux
(cont’d)

Low Battery Disconnect

Default

Delay Time Sec

Default 01 second

Range: 000 to 250 sec.

DISCONNECT VOLTS

Default 13.6 Vdc

Range: 10 to 80 sec.

RECONNECT VOLTS

Default14.4 Vdc

Range: 10 to 80 sec.

Remote

Default

Light

MODE

Default

Auto Time

Default 2 minutes

Range: 1 to 9 minutes

EQ

BATTERY EQUALIZE Volts

Default 14.4 Vdc

Range: Absorbing

setting to 80 Vdc

BATTERY EQUALIZE Time

Default 01 hours

Range: 1 to 7 hours

EQ INTERVAL

Default 000 days

Range: 000 to 250 days

Advanced

Snooze Mode

Default 0.6 Adc

Range: 0.2 to 1.0 Adc

Wakeup Mode Volts

Default 1.5 Vdc

Range: 1.5 to 9.5 Vdc

Wakeup Mode Time

Default 05 minutes

Range: 05 to 15 min.

MPPT Mode

Default

or

U-Pick>

Park Mpp

Default 77% Voc

Range: 40 to 90% Voc

MPP Range Limit (Max)

Default <90%>

<80, 85, 90, 99%>

MPP Range Limit (Min)

Default <1/2>

<1/2 or FULL>

Absorb Time Limits

Default 01.0 hours

Range: 00.0 to 24 hours

Absorb End Amps

Default 00 Adc

Range: 00 to 55 Adc

Rebulk Voltage

Default 12.0 Vdc

Range: 12.0 Vdc to

Float setting

Vbatt Calibration

Default 0.0 Vdc

Range: -0.5 to 0.5 Vdc

RTS Compensation
Upper Limit

Default 14.1 Vdc

Range: Lower Limit

setting to 80 Vdc

RTS Compensation
Lower Limit

Default 14.1 Vdc

Range: 10 Vdc to Upper

Limit setting

Auto ReStart

Default <0>

Selections <0, 1 , 2>

Aux Polarity

Default

or Low>