Specifications
94
900-0009-01-00 Rev
C
Default Settings and Ranges
Table 4
FLEXmax Settings
Mode
Menu Item
Setting
Charger
Current Limit (FLEXmax 80)
Default 80 Adc
Range: 5 to 80 Adc
Current Limit (FLEXmax 60)
Default 60 Adc
Range: 5 to 60 Adc
Absorbing
Default 14.4 Vdc
Range: Float setting to
80 Vdc
Float
Default 13.8 Vdc
Range: 12.0 Vdc to
Absorbing setting
Aux
Vent Fan
Default
Volts
Default 14.4 Vdc
Range: 10. 0 to 80.0 Vdc
PV Trigger
Default
Hold Time Sec
Default 01.1 second
Range: 0 to 25 seconds
PV VOLTS
Default 140 Vdc
Range: 20 to150 Vdc
ERROR OUTPUT
Default
ERROR LOW BAT
VOLTS
Default 11.5 Vdc
Range: 10 to 80 Vdc
Night Light
Default
ON Hysteresis Time
(Minutes)
Default 001 minute
Range: 001 to 255 min.
On Time (Hours)
Default 04 hours
Range: 00 to 23 hours
Threshold Voltage
Default 010 Vdc
Range: 005 to 150 Vdc
Float
Default
Diversion:Relay
Default
Hold Time (Seconds)
Default 0.1 second
Range: 0.0 to 25 sec.
Delay Time (Seconds)
Default 0.0 seconds
Range: 0.0 to 24 sec.
Absorb-Float-EQ
Relative Volts
Default 0.0 Vdc
Range: 0.0 to 5.0 Vdc
HYST
Default 00.2 Vdc
Range: 0.0 to12.0 Vdc
Diversion:Solid St
Default
Hold Time (Seconds)
Default 0.1 second
Range: 0.0 to 25 sec.
Delay Time (Seconds)
Default 00 seconds
Range: 00 to 24 sec.
Absorb-Float-EQ
Relative Volts
Default 0.0 Vdc
Range: 0.0 to 5.0 Vdc
HYST
Default 00.2 Vdc
Range: 0.0 to12.0 Vdc
Mode
Menu Item
Setting
Aux
(cont’d)
Low Battery Disconnect
Default
Delay Time Sec
Default 01 second
Range: 000 to 250 sec.
DISCONNECT VOLTS
Default 13.6 Vdc
Range: 10 to 80 sec.
RECONNECT VOLTS
Default14.4 Vdc
Range: 10 to 80 sec.
Remote
Default
Light
MODE
Default
Auto Time
Default 2 minutes
Range: 1 to 9 minutes
EQ
BATTERY EQUALIZE Volts
Default 14.4 Vdc
Range: Absorbing
setting to 80 Vdc
BATTERY EQUALIZE Time
Default 01 hours
Range: 1 to 7 hours
EQ INTERVAL
Default 000 days
Range: 000 to 250 days
Advanced
Snooze Mode
Default 0.6 Adc
Range: 0.2 to 1.0 Adc
Wakeup Mode Volts
Default 1.5 Vdc
Range: 1.5 to 9.5 Vdc
Wakeup Mode Time
Default 05 minutes
Range: 05 to 15 min.
MPPT Mode
Default
U-Pick>
Park Mpp
Default 77% Voc
Range: 40 to 90% Voc
MPP Range Limit (Max)
Default <90%>
<80, 85, 90, 99%>
MPP Range Limit (Min)
Default <1/2>
<1/2 or FULL>
Absorb Time Limits
Default 01.0 hours
Range: 00.0 to 24 hours
Absorb End Amps
Default 00 Adc
Range: 00 to 55 Adc
Rebulk Voltage
Default 12.0 Vdc
Range: 12.0 Vdc to
Float setting
Vbatt Calibration
Default 0.0 Vdc
Range: -0.5 to 0.5 Vdc
RTS Compensation
Upper Limit
Default 14.1 Vdc
Range: Lower Limit
setting to 80 Vdc
RTS Compensation
Lower Limit
Default 14.1 Vdc
Range: 10 Vdc to Upper
Limit setting
Auto ReStart
Default <0>
Selections <0, 1 , 2>
Aux Polarity
Default