Logging, Operation – Outback Power Systems FLEXmax 80 Owners Manual User Manual
Page 56
![background image](/manuals/407201/56/background.png)
Operation
54
900-0009-01-00 Rev
C
Logging
The Logging screen in the main menu enables the user to clear the daily and cumulative logs if
necessary. Logs can be downloaded to an SD card if a MATE3 is installed. See page 69 for details.
The FLEXmax daily log begins when the controller enters Wakeup. See page 24.
IMPORTANT:
If two or more charge controllers are used in the same system and are started up or
cleared on different days, their numeric dates will not be the same. This can lead to
some misunderstandings when looking back and comparing data between the two or
more units. A user looking back at day 12 on both units would find very different
results.
Figure 48
Logging Mode
To clear the logs:
1.
From the main menu, press <> to move the arrow next to
Logging.
2. Press
summary screen.
3.
Press the second soft key (SK2) to bring up the CLEAR Log
screen. The CLEAR LOG screen offers the option of clearing
up to 128 days of accumulated statistics or the total in the
secondary STATS screen (page 56).
4.
Press and hold either
those specific statistics. The Are you sure? screen appears.
5. Pressing
6. Press
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT
GO
Main Menu
Charger Aux Light
EQ Misc Advanced
Logging
Stats
EXIT
GO
Today 000Ah 00.0kWH
011Vp 00.0Ap 0.00kWp
MAX 14.7 V ABS 01:00
MIN 14.6 V FLT 00:00
CLEAR LOG
BACK TOTL DAILY
Are you Sure?
NO YES
Today 000Ah 00.0kWH
011Vp 00.0Ap 0.00kWp
MAX 14.7 V ABS 01:00
MIN 14.6 V FLT 00:00
End-of-Day Summary
Screen
Pressing SK3 and SK4 changes the displayed day’s
statistics, by moving either forward or backward within