Specifications, Electrical and mechanical specifications, Firmware revision – Outback Power Systems FLEXmax 80 Owners Manual User Manual
Page 95: Regulatory specifications
![background image](/manuals/407201/95/background.png)
900-0009-01-00 Rev
C
93
Specifications
Electrical and Mechanical Specifications
Specification
FLEXmax 60
FLEXmax 80
Output Current Rating @ 40°C ambient
60 amps continuous
80 amps continuous
Nominal Battery System Voltage
12, 24, 36, 48 or 60 Vdc (adjustable)
PV open circuit voltage
150 Vdc maximum (ETL Rating for UL1741 Standard);
145 Vdc temperature corrected Voc (operational maximum)
Standby power consumption
Less than 1 watt typical
Charge cycle
Three-stage
Voltage regulation set points
13-80 Vdc
Temperature compensation
5 mV per °C per 2 V cell (with optional RTS)
PV input capability
Down convert from any acceptable array voltage to any battery voltage.
Examples: 72 Vdc array to 24 Vdc battery; 60 Vdc array to 48 Vdc battery
Digital Display
4-line, 20-character per line backlit LCD display
Remote Interface
RJ45 modular connector Cat 5 cable 8 wire
Operating Temperature Range*
-40° to 60°C (automaticaly derated above 40°C)
Conduit knockouts
One 1” on the back; one 1” on the left side; two 1” on the bottom
Warranty
Five years parts and labor
Dimensions
13.5” H x 5.75” W x 4” D
16.25” H x 5.75” W x 4”D
Shipping Dimensions
18” H x 11” W x 8” D
21” H x 10.5” W x 9.75”D
Weight
11.6 lb (14 lb boxed)
12.20 lb (15.75 lb boxed)
Options RTS, HUB 4, HUB 10, MATE, MATE2, MATE3
Menu Languages
English and Spanish
Firmware Revision
This manual applies to FLEXmax 80 or FLEXmax 60 charge controllers with a firmware revision of
002.001.xxx or higher.
Regulatory Specifications
Table 3
Regulatory Specifications for All Models
UL 1741 1st Edition; 2005 Version, CSA 107.1-01
CE Conformance European EN 55022 Class B