Operation

52

900-0009-01-00 Rev

C

Auto ReStart (Advanced Menu)

This setting allows the user to choose between continuous maximum power point (MPP) tracking, or
occasional restarts of the sweeping process. A restart means the controller abandons the existing
maximum power point value it was using and “re-sweeps”, or begins gathering new power point data.
(See page 95 for more information on MPP tracking.)

Auto ReStart has three options available:

Mode 0 – Initial sweep only and then continuous MPP tracking. Auto ReStart is disabled. The FLEXmax will

continously track the maximum power point without starting over.

Mode 1 – Automatic re-sweep every 90 minutes if controller is in an MPPT mode (MPPT Float, MPPT

Bulk, etc). This will not reset any counters, charging stages, or statistics.

Mode 2 – Automatic re-sweep every 90 minutes if controller is in any charging mode. This will not reset any

counters, charging stages, or statistics.

Figure 45

Auto ReStart

ADVANCED MENU
Auto ReStart
MODE 0
EXIT NEXT MODE

Auto ReStart Screen

To select an Auto ReStart mode:

1.

Navigate to the Auto ReStart screen through the
ADVANCED MENU as instructed in Figure 35.

2. Press

to switch between the three Auto

ReStart modes: MODE 0 (default), MODE1, and
MODE2.

ADVANCED MENU
Auto ReStart
Mode 0
EXIT NEXT MODE

ADVANCED MENU
Auto ReStart
MODE 1
EXIT NEXT MODE

ADVANCED MENU
Auto ReStart
MODE 2
EXIT NEXT MODE

To Exit:
 Press to advance to the Aux Polarity screen.
 Press once to return to the main menu.
 Press twice to return to the status screen.