Operation
900-0009-01-00 Rev
C
41
Remote (AUX Mode)
Remote allows an OutBack system display to control the charge controller's auxiliary output. Some
displays may require a certain level of software in order to use this feature. Consult the owner's
manual for the system display being used for details.
Figure 29
Setting the Remote Mode
Backlight
The Backlight selection allows the LCD and soft keys to remain illuminated for up to nine minutes
whenever any soft key is pressed. The default setting for this mode is AUTO. Pressing any soft key
when the LCD is not illuminated does not change any settings.
Figure 30
Operating the Backlight
To set the mode for Backlight:
1.
From the main menu, press <> or <> to move the to
the left of Light.
2. Press
3. Press
< MODE> to cycle through ON, OFF, or AUTO.
ON activates the backlight.
OFF deactivates the backlight.
AUTO activates the backlight on a timer.
4. Press
<-> or <+> to increase or decrease the number of
minutes (up to 9) for the Auto Time mode.
5. Press
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT
GO
Main Menu
BACKLIGHT CONTROL
Auto Time 2 Minutes
AUTO
EXIT - + MODE
Charger Aux
Light
EQ Misc Advanced
Logging Stats
EXIT
GO
To Exit:
Press
Press
To set the mode for Remote:
1.
From the main menu, press <> or <> to move the
to the left
of the Aux.
2. Press
3. Press
screen.
4. Press
ON activates the AUX output.
OFF deactivates the AUX output.
AUTO controls the output according to the criteria of the
selected AUX mode. This setting may be required depending on
the type of system display being used.
Charger Aux
Light
EQ Misc Advanced
Logging Stats
EXIT
GO
Main Menu
AUX MODE
Remote
Output: Off Off
EXIT NEXT SET MODE
Charger
Aux
Light
EQ Misc Advanced
Logging Stats
EXIT
GO
To Exit:
Press
Press
The FLEXmax AUX output can be used for the AGS (Advanced Generator
Start) function of a system display. Remote must be activated for this to
work. The system display must be set to the HUB port used by the FLEXmax.
See the system display manual for more information on AGS. If using a
MATE, see page 81 of this book. If using a MATE3, see page 67.