Operation
900-0009-01-00 Rev
C
37
Diversion:Solid St (AUX Mode)
Figure 26
Setting the Diversion:Solid St AUX Mode (Part 1)
IMPORTANT
:
If using wind or hydroelectric turbines,
keep the charge controller’s diversion
voltage slightly above its Absorb and Float
voltage settings for efficient functioning.
Do not use Diversion:Solid St with a
mechanical relay. The PWM action could
cause irregular relay activity.
Diversion:Solid St requires the use of a
purely resistive load. The PWM action may
work poorly with mechanical loads.
To set the mode for Diversion:Solid St:
1.
From the main menu, press <> or <> to move the to the
left of Aux.
2. Press
3. Press
the AUX MODE screen.
4. Press
ON activates the AUX output.
OFF deactivates the AUX output.
AUTO controls the output according to the criteria of the
selected AUX mode.
Continued on next page...
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT
GO
Main Menu
Charger
Aux
Light
EQ Misc Advanced
Logging Stats
EXIT
GO
AUX MODE
Diversion:Solid St
Output: Off Off
EXIT NEXT SET MODE
next AUX MODE screen.