beautypg.com

Operation, Figure 32 setting the eq auto interval – Outback Power Systems FLEXmax 80 Owners Manual User Manual

Page 45

background image

Operation

900-0009-01-00 Rev

C

43

Figure 32

Setting the EQ AUTO Interval

In 11.6V 0.0 A
Out 13.8V 0.0 A
0.000 kW 0.0 kWH
AUX: OFF

EQ-MPPT

Status Screen

In 11.6V 0.0 A
Out 13.8V 0.0 A
0.000 kW 0.0 kWH
AUX: OFF

EQ 0:00

On the Status Screen:

EQ-MPPT will display to indicate the FLEXmax is trying to reach

the target equalize set point.

EQ 0:00 in Hours:Minutes will display after the equalize set point

is reached.

 After recharging, an EQ DONE message displays and a Float

cycle begins. EQ DONE is displayed until (1) any soft key is
pressed, or (2) a new day occurs for systems using an OutBack
system display.

The incomplete equalization cycle continues into the next day unless
the FLEXmax is powered off or manually stopped. The remaining EQ
time can be viewed in the End-of-day Summary screen (see page 18).

In 11.6V 0.0 A
Out 13.8V 0.0 A
0.000 kW 0.0 kWH
AUX: OFF

EQ DONE

BATTERY EQUALIZE
1 Hours 15.0 Volts
Check water level
BACK AUTO START STOP

COUNT EQ INTERVAL
000 000

EXIT -DAY +DAY

Equalization Interval

Screen

COUNT EQ INTERVAL
000 000

EXIT -DAY +DAY

Automatic Equalization Mode

To enable an automatic equalization mode, an interval must be set for the number of days to pass between
equalization cycles. This interval can be between 1 to 250 days. The default equalization interval setting is 000
which disables this feature.

The Equalization Interval screen allows the user to set the interval between equalization cycles. It also displays
how many days of the interval has passed. The COUNT value will be cleared to 000 when an equalization cycle is
started, manually stopped, or if the charge controller has been powered off.

BATTERY EQUALIZE

START Screen

To enable an automatic EQ cycle:

1. Press

to display the equalization interval screen.

2. Use

<-DAY> or <+DAY> to set the number of days between each

equalization cycle.

3. Press

to return to the status screen.

EQ INTERVAL

(1 to 250)

Days of the interval
that have elapsed

Equalization Interval

Screen

To Exit:
 Press once to return to the EQ screen.

This manual is related to the following products: