Charge Controller Settings

Charge Controller menu options include the following:

Charger

------------------------------------------------------------- >

See page 64.

MPPT

---------------------------------------------------------------- >

See page 64.

Temperature Compensation

------------------------------- >

See page 65.

Battery Equalize

------------------------------------------------ >

See page 65.

Grid-Tie Mode

--------------------------------------------------- >

See page 65.

Auxiliary Output

------------------------------------------------ >

See page 66.

Restart Mode

----------------------------------------------------- >

See page 67.

Calibrate

----------------------------------------------------------- >

See page 68.

Reset Charge Controller to Factory Defaults

-------- >

See page 68.

Charger

IMPORTANT:

Battery charger settings need to be correct for a given battery type. Always follow battery
manufacturer recommendations. Making incorrect settings, or leaving them at factory default
settings, may cause the batteries to be undercharged or overcharged.

The charge controller uses a “three-stage” battery charging cycle which utilizes multiple settings. This
menu controls the voltages and timers for the battery charger. See page 96 for an explanation of the
three-stage cycle and a description of the individual stages.

Figure 61

Charger

MPPT

The charge controller uses a maximum power point tracking (MPPT) algorithm which manipulates the
output of the PV array to harvest maximum wattage. Although this function is automatic, this menu
allows the user to adjust many of its parameters for special applications. See page 47, 48, and 100.

Figure 62

MPPT

Set Points:

MPPT Mode
U-Pick VOC
Wakeup VOC Change VDC and Wakeup VOC

Change Time – The FLEXmax screen refers to these
items under the title “Wakeup Mode”

Snooze Mode Amps
MPP Range Minimum and MPP Range Maximum

The FLEXmax screen refers to these items under the
title “Mpp Range Limit %”

Set Points:
Absorb Voltage
(Absorb) Time
Float Voltage
Rebulk Voltage
Current Limit

Absorb End Amps