Applications

900-0009-01-00 Rev

C

101

Figure 102 Adjusting Range Limits for Hydroelectric or Fuel-cell Applications

Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT

  GO

Main Menu

Charger Aux

Light

EQ Misc

Advanced

Logging Stats
EXIT

 

GO

ADV SETUP Screen

ADVANCED MENU
MPPT Mode
Auto Track
EXIT NEXT nonGT MODE

MPPT Mode (Auto Track)

To adjust the Lower Mpp Range Limit:

1.

From the main menu, press <> to move the arrow next to
the Advanced function.

2. Press

.

3. In

the

ADVANCED MENU screen, press again to

display the Mpp Range Limit % Voc screen.

4. Press

<1/2> until FULL appears.

5. When

finished,

press

until the MPPT Mode

screen appears.

ADVANCED MENU
Park Mpp
Watts 0251 77 % Voc
EXIT NEXT -% +%

U-pick% (Voc) MPPT

ADVANCED MENU
Mpp Range Limit %VOC
Min Max
EXIT NEXT 1/2 90%

Mpp Range Limit % Voc

ADVANCED MENU
Snooze Mode
< 0.6 amp
EXIT NEXT AMP

To pick between Auto Track or U-Pick % MPPT Mode and determine the
charge controller’s operating Voc percentage, press to interchange
between the two modes.

Re-entering the password might be required. After choosing a mode, press
in the ADVANCED MENU to view the Park Mpp screen (only
applicable for U-Pick mode).

Press < -%> or <+%> to select one of the percentage values; U-Pick always
uses the Park Mpp value.