beautypg.com

Log screens, Mate/mate2 screens – Outback Power Systems FLEXmax 80 Owners Manual User Manual

Page 77

background image

MATE/MATE2 Screens

900-0009-01-00 Rev

C

75

LOG Screens

Figure 84

LOG Screens

Navigation for STATUS/CC/LOGS

returns to the CC/PG2 screen.
moves to the next menu item

in the diagram.

moves to the previous menu item

in the diagram.

returns to the 1

st

CC/LOG1 screen

for the port shown.

directs the MATE to read the

next device (port) on the HUB.

displays log information from

one day earlier. Logs can be displayed
from as far as 128 days in the past.

displays log information from

one day later. If the present day is
displayed, then pressing this key will
return the log to 128 days in the past.

STATUS/CC/METER----P00
end of cc logs display

TOP STATUS

STATUS----------------
choose device

FX CC DC MAIN

MAIN------------------
1:35:04p

SUM STATUS SETUP ADV

STATUS/CC/PAGE1


MODE METER SETPT PG2

STATUS/CC/PAGE2-------


PG1 LOGS STAT MAIN

STATUS/CC/LOG1-----P00
TODAY 0 AH 00.0 kWH
21Vp 00.0Ap 0.00kWp
DOWN DAY- DAY+ PORT

STATUS/CC/LOG2-----P00
TODAY battery
max 14.5V min 14.4V
DOWN DAY- DAY+ PORT

STATUS/CC/LOG3-----P00
TODAY absorb float
00:00 00:00
DOWN DAY- DAY+ PORT

Charge Controller Logs

The LOG screens contain information
collected from the FLEXmax on individual
days. These logs include daily accumulated
amp-hours and kilowatt-hours, and peak
readings for power, current, and voltage. It
also includes the timers for the FLEXmax
battery charger. This data is the same as
that shown on the FLEXmax End-of-Day
Summary
screen (see page 18.)

Log 1 Today:

AH (accumulated battery amp-hours)
Kwh (accumulated battery

kilowatt-hours)

Vp (peak PV voltage)
Ap (peak PV current)
kWp (peak PV kilowatt-hours)

Log 2 Today:

max V (maximum battery voltage)
min V (minimum battery voltage)

Log 3 Today:

absorb timer
float timer

This manual is related to the following products: