Operation, Figure 34 miscellaneous screen #2 – Outback Power Systems FLEXmax 80 Owners Manual User Manual
Page 47
![background image](/manuals/407201/47/background.png)
Operation
900-0009-01-00 Rev
C
45
Figure 34
Miscellaneous Screen #2
GT STATE PWM% ChgT
255 07 50.0 005
EXIT NEXT RSTRT
Misc Screen #1
FORCE
EXIT NEXT FLOAT BULK
To bring the charge controller out of Snoozing mode:
1. Press
2. Press
Force Bulk/Float Screen
PCB Target BTMP CFB
512 14.4v 255 0712
EXIT BACK
Press
Force Bulk/Float screen.
Press
the main menu.
PCB
Target BTMP CFB
512
14.4v 255 0712
EXIT BACK
PCB
Target
BTMP CFB
512
14.4v
255 0712
EXIT BACK
PCB Target
BTMP
CFB
512 14.4v
255
0712
EXIT BACK
PCB Target BTMP
CFB
512 14.4v 255
0712
EXIT BACK
PCB represents the temperature of the internal components. It
is used to control the cooling fan. These values are in digital
counts, not degrees. The lower the number, the higher the
temperature. (25°C is approximately a value of 525.)
BTMP is a battery temperature sensor reference value, used to
compensate the charging voltage. The range is 0 to 255. These
values are in digital counts, not degrees.
An X next to this value indicates an external RTS is being used in a
system with a HUB and system display.
The target voltage the controller is trying to reach. This will
depend on the active stage of the charger and the set target
value for that stage.
CFB represents Current FeedBack. This is the output value of the
internal current sensor and is used to calculate output amps and
watts to track the maximum power point of the array.
Misc Screen #2
GT STATE PWM% ChgT
255 07 50.0 005
EXIT NEXT RSTRT
Misc Screen #1
To force the charger into a Bulk or Float charge cycle:
1. Press
2.
Select either a Float or Bulk charge cycle. Forcing a Float or
Bulk recharge will end an EQ cycle. See page 20 for details on
these modes.
Press
Press
3. Press
press