Operation – Outback Power Systems FLEXmax 80 Owners Manual User Manual
Page 38
![background image](/manuals/407201/38/background.png)
Operation
36
900-0009-01-00 Rev
C
Figure 25
Setting the Diversion:Relay Mode (Part 2)
To change the set points for Diversion:Relay:
1. Press
2. Press
to advance to the Time screen. This allows the user
to adjust the minimum time the AUX output is active after the
battery voltage falls below the hysteresis voltage.
3. Press
<-> or <+> to increase or decrease the Hold time values.
4. Press
5. Press
screen.
6. Press
7. Press
<-> or <+> to increase or decrease the values.
8. Press
9. Press
VOLT screen.
10. From
the
Diversion:Relay screen, press
AUX MODE screen.
AUX MODE
Diversion:Relay
EXIT TIME VOLT
Absorb--Float--EQ
Relative Volts
0.0 00.2
BACK - + HYST
Hold Delay
01.0 Time 00
Seconds
BACK - + DLY+
Hold time shows how long the AUX output
stays active after the battery voltage has
fallen below the HYST (hysteresis) set point.
The user can adjust the Hold time from 0.1
to 25 seconds.
The Delay time shows how long the
battery voltage must be above the Relative
Volts before the AUX mode is activated. It
can be adjusted from 0 to 24 seconds, but is
rarely required.
Pressing the
AUX MODE Diversion: Relay TIME and
VOLT screen.
Use this screen to establish the set points for starting
and ending the AUX mode relative to the Absorb,
Float, and EQ voltages.
The
the AUX mode becomes inactive after the battery
voltage falls below the Relative Volts voltage minus
the hysteresis value.
...continued from previous page.
AUX MODE
Diversion:Relay
Output: Off Off
EXIT NEXT SET MODE
To Exit:
Press
to the main menu.
Press
to the status screen.