Advanced Menu

The Advanced menu allows fine-tuning of the FLEXmax operations including Snooze periods and
Maximum Power Point limits (see page 95). The following modes are available in the Advanced menu.
They will appear in the following order.

Snooze Mode
Wakeup
MPPT Mode
Park Mpp
Mpp Range Limit % Voc
Absorb Time
Rebulk Voltage
Vbatt Calibration
RTS Compensation
Auto Restart
Aux Polarity
Reset to Defaults?

Figure 35

Accessing the Advanced Menu

Snooze Mode (Advanced Menu)

Snoozing occurs if the charging current does not reach the user-selected cutoff current set point as
shown in this screen.

Figure 36

Snooze Mode

To adjust the set point in the Snooze Mode screen:

1.

Navigate to the Snooze Mode screen through the
ADVANCED MENU as instructed in Figure 35.

2. Press

to adjust the amp setting.

Amp values increments include: 0.2, 0.4, 0.6, 0.8 and 1.0.

3. Press

to advance to the Wakeup Mode screen.

To Exit:
 Press once to return to the main menu.
 Press twice to return to the status screen.

ADVANCED MENU
Snooze Mode
< 0.6 amp
EXIT NEXT AMP

Snooze Mode

To Access the Advanced Menus:

1.

From the main menu, press <> or <> to move the

to the left of Advanced.

2. Press

to open the first Advanced menu screen.

3. Press

to cycle through the available modes. The

Snooze Mode screen should be the first screen to display.

4. Press

to return to the status screen.