Charger screen, Operation – Outback Power Systems FLEXmax 80 Owners Manual User Manual
Page 28
![background image](/manuals/407201/28/background.png)
Operation
26
900-0009-01-00 Rev
C
Charger Screen
Charging settings should follow the battery manufacturer's recommendations. This screen allows
changes to the recharging voltage set points if the default settings do not match the manufacturer's
recommendations. (For an explanation of battery charging, see pages 96 and 97).
Current Limit
Absorbing
Float
The default charger output current limit setting is:
80 amps for the FM80, and
60 amps for the FM60.
This setting is adjustable from 5-80 amps.
IMPORTANT:
Check the battery manufacturer’s recommendations for the optimal charging
settings for the type of batteries being used.
An appropriate circuit breaker, or overcurrent device, must be used between the
battery and the FLEXmax.
If a battery remote temperature sensor (RTS) is used, set the Absorbing and Float
setting voltage based on a 25°C/77°F setting. RTS compensated voltage values can
be viewed in the Advanced menu screen under the RTS Compensation heading.
Figure 18
Charger Setup Menu
Charger
Aux Light
EQ Misc Advanced
Logging Stats
EXIT
GO
Current Limit
80A
Absorbing 14.4V
Float 13.8V
EXIT
- +
To access the Charger screen and adjust the settings:
1.
From the main menu, press the <> or <> soft key to
move the
to the left of the Charger function.
2. Press
The indicates which set point is selected.
3. Press
<> to move the to the set point that needs to
be changed.
4. Press
<+> to increase the value or (–) to decrease
the value.
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT
GO
Main Menu
Charger Screen
To Exit:
Press
Press