beautypg.com

Charger screen, Operation – Outback Power Systems FLEXmax 80 Owners Manual User Manual

Page 28

background image

Operation

26

900-0009-01-00 Rev

C

Charger Screen

Charging settings should follow the battery manufacturer's recommendations. This screen allows
changes to the recharging voltage set points if the default settings do not match the manufacturer's
recommendations. (For an explanation of battery charging, see pages 96 and 97).

Current Limit
Absorbing
Float

The default charger output current limit setting is:

 80 amps for the FM80, and
 60 amps for the FM60.

This setting is adjustable from 5-80 amps.

IMPORTANT:

 Check the battery manufacturer’s recommendations for the optimal charging

settings for the type of batteries being used.

 An appropriate circuit breaker, or overcurrent device, must be used between the

battery and the FLEXmax.

 If a battery remote temperature sensor (RTS) is used, set the Absorbing and Float

setting voltage based on a 25°C/77°F setting. RTS compensated voltage values can
be viewed in the Advanced menu screen under the RTS Compensation heading.

Figure 18

Charger Setup Menu

Charger

Aux Light

EQ Misc Advanced
Logging Stats

EXIT

  GO

Current Limit

 80A

Absorbing 14.4V
Float 13.8V
EXIT

 - +

To access the Charger screen and adjust the settings:

1.

From the main menu, press the <> or <> soft key to
move the

to the left of the Charger function.

2. Press

to open the Charger screen.

The  indicates which set point is selected.

3. Press

<> to move the  to the set point that needs to

be changed.

4. Press

<+> to increase the value or (–) to decrease

the value.

Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT

  GO

Main Menu

Charger Screen

To Exit:

 Press once to return to the main menu.
 Press twice to return to the status screen.

This manual is related to the following products: