Fibre channel driver – HP IP Distance Gateway User Manual
Page 116

Fibre Channel driver
lists informational log messages common to both FC ports, 1 (FC1) and 2
(FC2). Log messages beginning with #0 apply to Fibre Channel port 1 (FC1), and log messages
beginning with #1 apply to Fibre Channel port 2 (FC2).
Table 21 FC driver—Informational log messages
Description
No.
Log message
ID
Request to reset the FC
processor (adapter) received
from IOCTL interface.
98
#%d: QLIoctlDisable: Reset adapter
118882
LIP occurred. The LIP type is
reported, as is the contents of
304
#%d: QLIsrEventHandler: LIP occurred (%x): mailbox1 =
%x
119088
the FC processor’s mailbox 1
register.
Fibre Channel LIP reset
occurred. The LIP reset type is
305
#%d: QLIsrEventHandler: LIP reset occurred (%x): mailbox1
= %x
119089
reported, as is the contents of
the FC processor’s mailbox 1
register.
Fibre Channel link up occurred.
Event status is reported, as is
306
#%d: QLIsrEventHandler: Link up (%x) mailbox1 = %x
119090
the contents of the FC
processor’s mailbox 1 register.
Fibre Channel link up occurred.
Event status is reported, as is
308
#%d: QLIsrEventHandler: Link mode up (%x):
RunTimeMode=%x
119092
the RunTimeMode (0 = loop, 1
= point-to-point).
An RSCN was received. Event
status is reported, as is the
RSCN information.
309
#%d: QLIsrEventHandler: RSCN update (%x) rscnInfo: %x
119093
Fibre Channel port update.
Event status is reported, as is
313
#%d: QLIsrEventHandler: Port update (%x) mb1-3 %x %x
%x
119097
the contents of the FC
processor’s mailbox 1, 2, and
3 registers.
FCIP-Fibre Channel link up
occurred. Event status is
768
#%d: QLFcipIsrEventHandler: Link up (%x) mailbox1 = %x
119552
reported, as is the contents of
the FC processor’s mailbox 1
register.
FCIP-Fibre Channel link down
occurred.
769
#%d: QLFcipIsrEventHandler: Link down (%x)
119553
FCIP-Fibre Channel link up
occurred. Event status is
770
#%d: QLFcipIsrEventHandler: Link mode up (%x)
119554
reported, as is the
RunTimeMode (0 = loop, 1 =
point-to-point).
116
Log data