Required tools – HP EML E-series Tape Libraries User Manual
Page 89

IMPORTANT:
If you do not allow sufficient time for the interface controller to reset before resetting it again, the
Interface Manager card will not recognize the interface controller.
7.
Make sure the power LED and link LEDs on the interface controller are solid green. The link LEDs
indicate a good connection (see “
HP StorageWorks e2400-FC 4Gb interface controller
8.
Use HP StorageWorks Command View TL or the CLI to make sure that the new interface controller is
detected, and to perform configuration and firmware updates, if necessary.
Power supply in the base module or tape drive expansion
module
Part number
375815-001 or 409857–001
Location
Left side of the base module or tape drive expansion module
Characteristics
•
Hot-swappable
•
Input rating: 100–240 VAC, 50-60 Hz, 7.2A
•
Output rating: +3.3 VDC, +5 VDC, +12 VDC, -12 VDC
•
360 Watts total output power
Function
Provides power to the base module or tape drive expansion
module components
Illustration
10465
Required tools
•
T-15 Torx screwdriver
Removing a power supply from the base module or tape drive expansion module
1.
Identify the power supply to be replaced. The power LED might be off (see
Power supply in the base module or tape drive expansion module
2.
Do one of the following:
• If the faulty power supply is redundant, the library does not have to be powered off during
this procedure.
• If the faulty power supply is the only power supply in the base module, stop all library activity
and make sure the picker is empty. Turn off the power to the library.
3.
Unplug the power cord from the back of the power supply.
4.
Remove the two 6-32 x 3/8-inch Torx screws that attach the power supply to the library. Use a
T-15 Torx screwdriver.
Enterprise Modular Library E-Series
89