Table 22 example setting, 22 example setting – HP StorageWorks XP Remote Web Console Software User Manual
Page 96
96
Hitachi TrueCopy z/OS for HP XP12000/XP10000 and SVS 200 storage systems
values: the initial copy pace, the max number of initial copy VOLs, the speed of the line between MCU
and RCU, and the number of lines.
The Cancel button cancels the registering RCU operation. The Set button sets the registering RCU operation
with the option you set on the RCU Option window.
NOTE:
You cannot use the PPRC commands to change the RCU options. For more information on PPRC
TSO and ICKDSF commands, see ”
Using PPRC commands for TrueCopy
Initial Copy response time (ms) = (1[MB]/“Speed of line between MCU-RCU[MB/ms]”
1
)
x (“initial copy pace”
2
/15)
x (“max number of initial copy VOLs”
3
/“Number of
lines between MCU-RCU”
4
)
1. When you connect MCU with RCU without lines etc., specify 0.17[MB/ms] in “Speed of line between MCU and RCU.”
2. For “initial copy pace” in the formula above, see
3. For the maximum number of initial copy volumes, see ”
” on page 25. The default is 64.
4. Even if “Max number of initial copy VOLs”/“Number of lines between MCU-RCU” is larger than 16, specify “Max number of
initial copy VOLs”/“Number of lines between MCU-RCU” as 16.
Table 21
Initial Copy Pace for Calculating The Initial Copy Response Time
Perform Initial
Copy Only
Perform Initial Copy and Update Copy
at a Time
Initial Copy Pace
Specified at the
Time of Pair
Creation is 1 to 8
Initial Copy Pace
Specified at the
Time of Pair
Creation is 9 to 15
Operation
Remote Web
Console
Initial copy pace
specified at the time
of pair creation
Initial copy pace
specified at the time
of pair creation
8
Business Continuity
Manager
Initial copy pace
specified at the time
of pair creation
Initial copy pace
specified at the time
of pair creation
8
PPRC command
(TSO/ICKDSF) and
CU emulation
type=3390
Initial copy pace
specified at the time
of pair creation
Initial copy pace
specified at the time
of pair creation
8
PPRC command
(TSO/ICKDSF) and
CU emulation
type=2150
or 2107
15
1
1. When a PPRC command (TSO/ICKDSF) is used and the CU emulation type is 2105
or 2107
, the initial copy pace specified is
invalid. Therefore, the fixed value will be set.
8
1
Table 22
Example setting
Item No.
Round Trip
Time [ms]
Line Speed
b/w
MCU/RCU
[MB/ms]
Number of
Lines b/w
MCU/RCU
Initial Copy
Pace
Max.
Number of
Initial Copy
VOLs
Round Trip
Time
Specified
[ms]
1
0
0.1
4
15
64
160
2
30
0.1
4
15
64
220
3
100
0.1
4
15
64
360