beautypg.com

Cgroup (freeze/run) command – HP StorageWorks XP Remote Web Console Software User Manual

Page 175

background image

Hitachi TrueCopy for z/OS user guide 175

For ESCON cable

:

For Fibre Channel cable:

ll

= Fibre-channel port ID of the secondary CU (RCU) from which the paths of the TCz should be

established.
For Fibre Channel cable: Fibre Channel port ID of the secondary CU (RCU) from which the paths of the

TC390 should be established.

cc

= LCU number of the secondary CU (RCU).

The parameters may be described in the GDPS DASD configuration list. The required link parameter values

must be written into the list or must be given to RCMF input.

Mode 59 (HXRC only): Mode 59 must be ON for HXRC (activates variable RECSET size to provide

performance improvement).

Mode 64 (optional): Mode 64 extends the range of the CGROUP command to the entire MCU instead

of just one logical CU image. When mode 64 is enabled, one CGROUP command to any M-VOL or

simplex volume in the MCU is executed across all MCU-RCU paths and on all TC390 M-VOLs in the

specified MCU, including all CU images (CU0-CU3). When mode 64 is disabled, you must issue a

separate CGROUP command to an M-VOL (or simplex volume) in each logical CU image of the MCU.

Although this mode can be enabled nondisruptively (that is, existing TC390 pairs do not have to be

deleted), mode 64 should be enabled at the same time that mode 49 is enabled.

NOTE:

For operations in a GDPS environment, mode 64 must be OFF.

Mode 104 (3990 only): Mode 104 changes the default FREEZE option to enabled. This mode should be

enabled when CGROUP is being used in the GDPS environment. When mode 104 is enabled, the

FREEZE option will remain enabled after the XP12000/XP10000 is powered off and then back on (for

example, due to some disaster). When mode 104 is not enabled, the FREEZE option will revert to the

default value of disabled after the XP12000/XP10000 is powered off and back on.

NOTE:

For operations in a GDPS environment, mode 104 must be ON.

Mode 104 is invalid for 2105 and 2107 emulation.
For more information on XP12000/XP10000 system option modes related to TC390 (and HXRC)

operations, see

Table 3

on page 18.

CGROUP (FREEZE/RUN) command

The CGROUP TSO command specifies all of the following:

The device (LDEV ID of TC390 M-VOL or simplex volume) (DEVN parameter).

The MCU (S/N and lowest SSID in CU image) (PRIM parameter).

The RCU (S/N and lowest SSID in CU image) (SEC parameter).

The CGROUP TSO command has the following two options:

Value

Port ID

Freeze Option

X’0000’-X’001F’

Interface 1A-2R

Default

X’0100’-X’011F’

Interface 1A-2R

Enabled

X’0200’-X’021

F’Interface 1A-2R

Disabled

Value

Port ID

Freeze Option

X’4000’-X’40FF’

Interface 1A-GR

Default

X’4100’-X’41FF

Interface 1A-GR

Enabled

X’4200’-X’42FF’

Interface 1A-GR

Disabled

This manual is related to the following products: