Figure 75 example of wwnn, 75 example of wwnn, Table 37 – HP StorageWorks XP Remote Web Console Software User Manual
Page 163: Figure 75

Hitachi TrueCopy for z/OS user guide 163
Figure 75
Example of WWNN
NOTE:
The parameter of PRIM and SEC of CDELPATH command are indicated as same as the parameter
of CESTPATH command.
If the subsystem is connected to the former type subsystem that does not support the Fibre Channel
interface, a unit check is reported.
The following table gives the XP12000/XP10000 system adapter ID (SAID) values for the CESTPATH LINK
parameter.
•
The last two digits of the link parameter must specify the logical CU number (00-1F for an
XP12000/XP10000, 00-0F for an XP256).
•
For 3990 controller emulation, the first two digits can be 00, 01, or 02. This option controls freeze as
follows:
00 = use mode 104
01 = freeze enabled
02 = freeze disabled
•
For 2105 or 2107 emulation, the first two digits must be 00. The CGROUP option of the CESTPATH
command is used to control freeze for 2105 or 2107 emulation.
Table 37
SAID Values for LINK parameters (ports) (FRONT CL1)
Package
Location
Port
SAID*
Package
Location
Port
SAID*
Package
Location
Port
SAID*
Package
Location
Port
SAID*
1E
CL1-A
X'0000' 1G
CL1-J
X'0008' 1K
CL9-N X'008C' 1B
CL9-E
X'0084'
(Basic)
CL3-A X'0020' (Add 2)
CL3-J
X'0028' (Add4)
CLB-N X'00AC' (Add6)
CLB-E
X'00A4'
CL5-A X'0040'
CL5-J
X'0048'
CLD-N X'00CC'
CLD-E
X'00C4'
CL7-A
X'0060'
CL7-J
X'0068'
CLF-N X'00EC'
CLF-E
X'00E4'
CL1-B
X'0001'
CL1-K
X'0009'
CL9-P
X'008D'
CL9-F
X'0085'
CL3-B
X'0021'
CL3-K
X'0029'
CLB-P
X'00AD'
CLB-F
X'00A5'
CL5-B
X'0041'
CL5-K
X'0049'
CLD-P
X'00CD'
CLD-F
X'00C5'
CL7-B
X'0061'
CL7-K
X'0069'
CLF-P
X'00ED'
CLF-F
X'00E5'