beautypg.com

Ickdsf considerations for truecopy volumes, N (see, Ickdsf considerations for – HP StorageWorks XP Remote Web Console Software User Manual

Page 140: Truecopy volumes

background image

140 Hitachi TrueCopy z/OS for HP XP12000/XP10000 and SVS 200 storage systems

NOTE:

If # is added to the end of a device ID, such as 00:3F#, the LDEV is an external volume.

For more information about external volumes, see Hitachi HPAV for system 390 User Guide for the

XP12000/XP10000.

M-VOL Fence Level (Synchronous only): Select the fence level for the new pair(s). The fence level

determines the conditions under which the MCU rejects write operations to the M-VOL. Never is

automatically set for an asynchronous pair. See

Performing TrueCopy pair operations

” on page 120

for more information about this pair option.
• Never: M-VOL is never fenced.
• Data: M-VOL is fenced when the MCU cannot successfully execute an update copy operation for

any reason.

• Status: M-VOL is fenced only if the MCU cannot change the R-VOL status to suspended when an

update copy operation fails.

CFW Data: Specifies whether the CFW data is copied to the R-VOL. For TCPD-MF, only Copy to R-VOL

is available.

Asynchronous Parameters (Async only):
• Error Level: Error level for the new pair(s): Group, or Volume.

NOTE:

To set the parameters on multiple volumes at once without changing individual parameters

per volume, make the box for the parameters you do not want to change blank. Only parameters

you input are changed.

Cancel: Cancels settings you made and closes the Change Pair Option panel.

Set: Sets parameters and closes the Change Pair Option panel.

To change the pair options for one or more TC390 volume pairs:

1.

Connect to the MCU of the pair(s) to be changed the options and start the TC390 software.

2.

From the CU Number tree on the TrueCopy main window, select the CU number of the correct CU

image.

3.

From the Volume list on the TrueCopy main window, select the TC390 volume pair(s) that you want to

modify the options. Select either TC390 Sync or Async pairs, but not both.

4.

Right-click to display the pop-up menu and click Change Pair Option. The Change Pair Option window

is displayed.

5.

From the Change Pair Option window, select the pair options for the selected pair(s), and click Set to

close the Change Pair Option window and set the parameters. The list changes to the Pair Settings

Parameter list (Change Pair Option). Repeat this step as needed to change the pair options for the

pair(s).

NOTE:

The options can be modified and/or canceled after you have set them. See ”

Modifying

parameters and omitting selected volumes

” on page 122.

6.

To execute the pair option change requests quickly, select the Use Time-Saving Model check box above

the Pair Settings Parameter list (Change Pair Option).

7.

Click Apply on the TrueCopy main window to change the options for the specified pair(s).

8.

From the TrueCopy main window, verify that the pair option change was completed successfully.

ICKDSF considerations for TrueCopy volumes

The XP12000/XP10000 supports the use of the ICKDSF utility program. ICKDSF performs functions for the

installation, use, and maintenance of DASD as well as service functions, error detection, and media

maintenance.

This manual is related to the following products: