CESTPAIR DEVN(X’dev#’) PRIM(X’ssid

cmd_param

X’cca’ X’lss’) SEC(X’ssidserial# X’cca’ X’lss’)

[MODE(COPY|NOCOPY|RESYNC)] [PACE(pace)] [CRIT(YES|NO)] [MSGREQ(YES|NO)]

If the first digit of the cmd_param is other than A, the disk array interprets this command as pair

establishment for TC390 Synchronous or SI390.

The consistency group nn must be registered prior to this command. Otherwise this command will be

rejected.

When MODE(RESYNC) is specified, the consistency group number n must be the consistency group

number to which the addressed device belongs. If a different number is specified, this command will be

rejected.

When MODE(RESYNC) is specified, the copy mode (synchronous or asynchronous) cannot be

changed. If a different copy mode is specified, this command will be rejected.

If the consistency group requirements (see

Consistency groups

” on page 48) are not satisfied, this

command may/may not be rejected.

The delay option prevents command retry delay for this pair when sidefile is above the HWM (see

Graduated delay sidefile management

” on page 32). If not specified correctly, command is rejected

(F/M=04).

Table 39

Using CESTPAIR to establish and resume TrueCopy Async pairs

Parameter

Contents

Description

cmd_param

AGnnd

nn = consistency group

number (00-7F) or master

volume number (00-FF: for

dummy pair mode).
d = 0, N, or D

Without MODE(RESYNC): Specifies the consistency group number

nn to which the volume pair will belong.
With MODE(RESYNC): Specifies that all M-VOLs in the consistency

group should be resynchronized (resumed).
nn must specify the consistency group number of the addressed

device or the master volume number. For dummy pair mode, nn

must specify the master volume number.
d specifies the delay option for command retry due to sidefile:

0 = normal delay for command retry starting at HWM (see

Graduated delay sidefile management

” on page 32).

N = no delay time: no command retry delay due to sidefile for

this pair. Use the N setting only for a limited number of critical

volumes.
D = dummy pair mode (nn must specify the master volume

number).

AVnnd

nn

= consistency group

number (00-7F) or master

volume number (00-FF: for

dummy pair mode).
d

= 0, N, or D

With MODE(RESYNC): Specifies that only the addressed device

should be re-synchronized.
nn must specify the consistency group number of the addressed

device or the master volume number. For dummy pair mode, nn

must specify the master volume number.
d

specifies the delay option for command retry due to sidefile:

0 = normal delay for command retry starting at HWM (see

Graduated delay sidefile management

” on page 32).

N = no delay time: no command retry delay due to sidefile for

this pair.

Use the N setting only for a limited number of critical

volumes.
D = dummy pair mode (nn must specify the master volume

number).

PACE

(pace)

Specifies the pace of the initial copy operation: 1-255, default=15

tracks.

CRIT

(YES)

Specifies the Error Level (TC390A pair option) of Group.

(NO)

Specifies the Error Level (TC390A pair option) of Volume.