Hitachi TrueCopy for z/OS user guide 155

The following table provides troubleshooting instructions for the TC390A suspension conditions caused by

the offloading timer asynchronous option, the group timeout options (copy pending and RCU ready), and

by MCU

R-VOL

The RCU received a request from the

MCU to suspend the pair. The M-VOL

suspend type is M-VOL by Operator or

R-VOL by Operator.

Resume the pair from the MCU.

by RCU

M-VOL

The MCU detected an error condition

at the RCU that caused the MCU to

suspend the volume pair. The R-VOL

suspend type is by MCU.

Clear the error condition at the RCU or

R-VOL. If you need to access the R-VOL,

delete the pair from the RCU.
If any data on the R-VOL has changed,

delete the pair from the MCU and then

restart the pair (Add Pair). If not, resume

the pair from the MCU.

Delete Pair to

RCU

M-VOL

The MCU detected that the R-VOL

status changed to simplex because the

user deleted the pair from the RCU.

The pair cannot be resumed because

the R-VOL does not have the

suspended status.

Delete the pair from the MCU and then

restart the pair. You should use the Entire

initial copy option to resynchronize the

pair. You can use the No Copy initial

copy option only if no data on the

M-VOL or R-VOL changed.

R-VOL Failure

M-VOL

The MCU detected an error during

communication with the RCU or an

I/O error during update copy. In this

case, the suspend type for the R-VOL is

usually by MCU.

Check the path status on the RCU Status

window (see

Table 30

on page 153).

Clear any error conditions at the

RCU/R-VOL. If you need to access the

R-VOL, delete the pair from the RCU.
If any data on the R-VOL has changed,

delete the pair from the MCU and then

restart the pair (Add Pair). If not, resume

the pair from the MCU.

MCU IMPL

M-VOL,

R-VOL

The MCU could not find valid control

information in its nonvolatile memory

during the IMPL procedure. This error

occurs only if the MCU is without

power for more than 48 hours (power

failure and fully discharged batteries).

Resume the pair from the MCU. The

MCU will perform an entire initial copy

operation in response to the resume pair

request.

Initial Copy

Failed

M-VOL,

R-VOL

The MCU suspended this pair during

the initial copy operation. The data on

the R-VOL is not identical to the data

on the M-VOL. Invalid track format can

cause this suspension.

Delete the pair from the MCU. Clear all

error conditions at the MCU, M-VOL,

RCU, and R-VOL. Reformat failed track

using ICKDSF. Restart the initial copy

operation using the Add Pair window.

by FREEZE

M-VOL,

R-VOL

All TC390 Synchronous pairs in the

MCU were suspended by the

CGROUP/RUN command.

Resume the pair(s) from the MCU using

Resume Pair or the CESTPAIR

(MODE=RESYNC) TSO command.

MCU P/S-OFF

R-VOL

(TC390A)

The MCU suspended all TC390A pairs

due to MCU power-off.

None. The MCU will automatically

resume these TC390A pairs during

power-on.

by Sidefile

Overflow

M-VOL,

R-VOL

The amount of sidefile exceeds the

specified current pending update data

rate and the RCU data is not

transferred within the specified

offloading timer.

Add cache memory, increase the number

of paths between MCU and RCU, or

decrease the number of Async pairs or

host I/Os.

Table 31

Troubleshooting suspended TrueCopy pairs (continued)

Suspend Type Applies to Description

Corrective Action