79 failure conditions (described in, Table – HP StorageWorks XP Remote Web Console Software User Manual
Page 181

Hitachi TrueCopy for z/OS user guide 181
NOTE:
The PPRC Support=Yes option must be selected on the RCU option window (see ”
” on page 87). If not, the host processor generates the system console message that
includes the SIM instead of the IEA494I or IEA491E message.
Figure 79
Failure conditions (described in
)
Table 46
XP12000/XP10000 response characteristics to failure conditions
Failure Condition
TC390 Pairs
Suspended?
Expected Messages
FREEZE
Function
Failure of all channel
interfaces on the MCU
No
No IEA480, IEA491, or IEA494 messages are
displayed.
Not
activated
Failure of a disk on the MCU
a. Failure of one
physical device in
a parity group
No
1.
IEA480 message (SIM for physical device
blocked or port of physical device blocked)
is displayed when the next I/O is issued to
any logical volume in the parity group.
2.
No IEA491 or IEA494 messages are
displayed.
Not
activated
b. Failure of two
physical devices in
a parity group
No
1.
IEA480 message (SIM for LDEV blocked) is
displayed when the next I/O is issued to
any logical volume in the parity group.
2.
No IEA491 or IEA494 messages are
displayed.
Not
activated