beautypg.com

Changing cu option settings, Figure 63 cu option settings list, 63 cu option settings list – HP StorageWorks XP Remote Web Console Software User Manual

Page 116

background image

116 Hitachi TrueCopy z/OS for HP XP12000/XP10000 and SVS 200 storage systems

Changing CU option settings

CU option settings are displayed by selecting CU from the tree on the Other Operations panel (see

Figure 63

).

Figure 63

CU option settings list

CU: Number of this CU (00 to 3F)

SIM Report: MCU reporting status for service-level remote-copy SIMs to the hosts

PPRC Support: Status of PPRC support for the host

SCP Time: Sate-change-pending (SCP) time. SCP Time of TrueCopy z/OS and the

state-change-pending time of FlashCopy Mirror Version 2 are the same. If you change the

state-change-pending time of TrueCopy z/OS, the state-change-pending time of FlashCopy Mirror

Version 2 changes simultaneously. If you also change the state-change-pending time of FlashCopy

Mirror Version 2, the state-change-pending time of TrueCopy z/OS changes. For more information on

state-change-pending time of FlashCopy Mirror Version 2, see the Hitachi ShadowImage z/OS user

guide.

To change the CU option settings:

1.

Click the Other Operations tab, and then select CU in the tree.

This manual is related to the following products: