Related topics – HP XP Racks User Manual
Page 86

Description
SSB2 code
The reverse resynchronization was rejected because the volume you specified is the P-VOL for XRC.
23A8
The pair was not restored because the volume you specified is the P-VOL for CC.
23A9
The pair task was rejected because the volume you specified as the S-VOL is the P-VOL for XRC.
23AA
The pair task was rejected because the volume you specified as the S-VOL is the P-VOL for CC.
23AB
The pair was not registered in the CG because IBM PPRC/BCM has reserved the specified CG number.
23AF
The pair was not created because the volume you specified as the S-VOL could not be used as the
S-VOL because of Volume Security settings.
23BB
The pair was not deleted because the P-VOL and S-VOL are in the process of being Quick Split.
23EF
The pair task was rejected because you set a split time for the CG.
23F5
The pair was not created because the CTG identifier you specified is not supported.
23F1
You cannot run the command because the system did not authenticate your user information.
9100
The pair task was rejected because the specified volume did not exist.
B911
The pair was not created because the specified S-VOL does not exist.
B912
The pair task was rejected because the mirror ID is invalid.
B913
Related topics
•
“Troubleshooting consistency group pair-split failures” (page 86)
.
Troubleshooting consistency group pair-split failures
If a consistency group (CG) pair-split fails, note the following:
•
The pairs in the CG are suspended (“Suspend/SUSPER” status).
•
If you are using a Cnt Ac-J Z S-VOL as an BC Z P-VOL and you are using RAID Manager to
run commands and the status for some pairs that are assigned to a CG are not changed,
some pairs remain unsplit in the CG and pair consistency is not guaranteed after you run the
following command:
pairsplit
The following are possible reasons why the status for some pairs that are assigned to a CG
are not changed:
◦
The Cnt Ac-J Z pair is assigned to a CG and the P-VOL and S-VOL have the same contents.
The journal volumes for this pair are full.
◦
The BC Z license is invalid.
◦
The BC Z pair volumes are blocked.
◦
The BC Z pair is in a status that does not allow you to run the pairsplit RAID Manager
command.
For more information about pair status, see
“Monitoring BC Z pair activity and status”
◦
You are using a BC Z pair volume in a Cnt Ac-S Z or Cnt Ac-J Z pair and the Cnt Ac-S Z
or Cnt Ac-J Z pair is in a status that does not allow you to run the pairsplit RAID
Manager command.
86