Pair user tasks during system and device maintenance
Check the following to determine whether pairs and pair user tasks are affected when you perform
maintenance on physical and logical devices:
•
To prevent one or more pairs from suspending, perform XP7 cache maintenance during a
period of low I/O usage. Reduce the I/O load before performing cache maintenance.
•
You can maintain the physical devices that contain LDEVs used by BC Z independently of pair
user tasks and pair status. Maintenance does not affect BC Z.
•
If a physical device failure occurs, the pair status is not affected because of the RAID
architecture.
•
If a physical device failure requires the XP7 storage system to utilize dynamic sparing or
automatic correction copy, the pair status is not be affected.
•
If an LDEV failure occurs, the XP7 storage system suspends the pair.
•
If an BC Z pair is using an LDEV, maintenance is restricted. You can block (for maintenance),
format, and restore the LDEV if it is used only by a pair in Suspend/SUSPER status.
Related topics
•
“Performance planning and calibrating your XP7 storage system” (page 18)
Workflow for maintaining the system
77