beautypg.com

HP XP Racks User Manual

Page 80

background image

It was rejected due to SKEY=0x05, ASC=0x20,SSB=0xB9E1,0xB901 on

Serial#(64015)

SSB1 code: B9E1

SSB2 code: B901

(If you are using RAID Manager or BCM operation log file)

Example error code:

11:06:03-37897-10413- SSB = 0xb9a0,2089

SSB1 code: b9a0

SSB2 code: 2089

3.

Locate the description of the SSB1/SSB2 error code combination in the following RAID Manager
or BCM error code table.

For more information about the errors that are not described in the table, contact HP Technical
Support.

Description

SSB2 code

An error occurred during a BC Z pair task.

-

The pair task was rejected because the specified THP or Smart V-VOL is not associated with a pool.

200D

The CG pair-split was rejected because the Cnt Ac-J Z pair is suspended (“Suspend/SUSPER” status),
unpaired, or is not split (“Split/SUSPOP” status). The Cnt Ac-J Z S-VOL was the BC Z P-VOL included
in the CG on which the pair-split is being performed.

201B

The Quick Restore was rejected because the cache mode of the specified P-VOL is different from the
cache mode of the external S-VOL.

2026

The volume you specified as a P-VOL was a volume using two mirrors included in a 3-Cnt Ac-J Z DC
multi-target or cascade configuration. The operation was rejected because the volume was used as
a Cnt Ac-J Z pair volume.

2043

The volume you specified as an S-VOL was a volume using two mirrors included in a 3-Cnt Ac-J Z DC
multi-target or cascade configuration. The operation was rejected because the volume was used as
a Cnt Ac-J Z pair volume.

2044

The pair task was rejected because the current microcode version does not support the specified P-VOL
capacity.

2047

The pair task was rejected because the current microcode version does not support the specified S-VOL
capacity.

2048

The pair task was rejected because of one of the following reasons:

205B

An MU number already in use is specified.

MU number 0 is assigned to an L2 pair.

The volume you specified as an BC Z P-VOL was a volume of a Cnt Ac-J Z pair. The pair task was
rejected because the status of the Cnt Ac-J Z pair is not in the required status.

2060

For more information about the required status for each pair task, see

“Pair status and supported pair

user tasks” (page 68)

.

The volume you specified as an BC Z S-VOL was a volume of a Cnt Ac-J Z pair. The pair task was
rejected because the status of the Cnt Ac-J Z pair is not in the required status.

2061

For more information about the required status for each pair task, see

“Pair status and supported pair

user tasks” (page 68)

.

Volumes of the specified pair are shared by Cnt Ac-S Z and Cnt Ac-J Z. The reverse resynchronization
was rejected because the Cnt Ac-S Z or Cnt Ac-J Z pair is not split (“Split/SUSPOP” status).

2067

80

Troubleshooting Business Copy Z

This manual is related to the following products: