HP XP Racks User Manual
Page 80
It was rejected due to SKEY=0x05, ASC=0x20,SSB=0xB9E1,0xB901 on
Serial#(64015)
SSB1 code: B9E1
SSB2 code: B901
•
(If you are using RAID Manager or BCM operation log file)
Example error code:
11:06:03-37897-10413- SSB = 0xb9a0,2089
SSB1 code: b9a0
SSB2 code: 2089
3.
Locate the description of the SSB1/SSB2 error code combination in the following RAID Manager
or BCM error code table.
For more information about the errors that are not described in the table, contact HP Technical
Support.
Description
SSB2 code
An error occurred during a BC Z pair task.
-
The pair task was rejected because the specified THP or Smart V-VOL is not associated with a pool.
200D
The CG pair-split was rejected because the Cnt Ac-J Z pair is suspended (“Suspend/SUSPER” status),
unpaired, or is not split (“Split/SUSPOP” status). The Cnt Ac-J Z S-VOL was the BC Z P-VOL included
in the CG on which the pair-split is being performed.
201B
The Quick Restore was rejected because the cache mode of the specified P-VOL is different from the
cache mode of the external S-VOL.
2026
The volume you specified as a P-VOL was a volume using two mirrors included in a 3-Cnt Ac-J Z DC
multi-target or cascade configuration. The operation was rejected because the volume was used as
a Cnt Ac-J Z pair volume.
2043
The volume you specified as an S-VOL was a volume using two mirrors included in a 3-Cnt Ac-J Z DC
multi-target or cascade configuration. The operation was rejected because the volume was used as
a Cnt Ac-J Z pair volume.
2044
The pair task was rejected because the current microcode version does not support the specified P-VOL
capacity.
2047
The pair task was rejected because the current microcode version does not support the specified S-VOL
capacity.
2048
The pair task was rejected because of one of the following reasons:
205B
•
An MU number already in use is specified.
•
MU number 0 is assigned to an L2 pair.
The volume you specified as an BC Z P-VOL was a volume of a Cnt Ac-J Z pair. The pair task was
rejected because the status of the Cnt Ac-J Z pair is not in the required status.
2060
For more information about the required status for each pair task, see
“Pair status and supported pair
.
The volume you specified as an BC Z S-VOL was a volume of a Cnt Ac-J Z pair. The pair task was
rejected because the status of the Cnt Ac-J Z pair is not in the required status.
2061
For more information about the required status for each pair task, see
“Pair status and supported pair
.
Volumes of the specified pair are shared by Cnt Ac-S Z and Cnt Ac-J Z. The reverse resynchronization
was rejected because the Cnt Ac-S Z or Cnt Ac-J Z pair is not split (“Split/SUSPOP” status).
2067
80
Troubleshooting Business Copy Z