HP XP Racks User Manual
Page 81

Description
SSB2 code
Because the specified P-VOL was also a Cnt Ac-J Z P-VOL for delta resync, one of the following errors
occurred:
2078
•
The Reverse Copy was rejected because the Cnt Ac-J Z pair status is not “Split/SUSPOP”.
•
The Quick Restore was rejected.
The pair task was rejected because the specified S-VOL was also a Cnt Ac-J Z P-VOL for delta resync.
2079
The pair task was rejected because the initialization process is being performed.
2086
The Quick Restore was rejected because you are formatting the volume you specified as a P-VOL
using Quick Format.
2089
For more information about formatting volumes using Quick Format, see the HP XP7 Provisioning for
Mainframe Systems User Guide.
The Quick Restore was rejected because you are formatting the volume you specified as an S-VOL
using Quick Format.
208A
For more information about formatting volumes using Quick Format, see the HP XP7 Provisioning for
Mainframe Systems User Guide.
The pair task was rejected because the volume you specified as the S-VOL is a FICON(R) Data
Migration volume.
208C
The Quick Restore was rejected because of one of the following:
2097
•
The P-VOL is also an THP V-VOL, but the S-VOL is a normal volume.
•
The P-VOL is a normal volume, but the S-VOL also an THP V-VOL.
The pair task was rejected because the volume you specified as the P-VOL is a Mainframe Fibre Data
Migration volume.
209E
The create pair task was rejected because the P-VOL is an THP or Smart V-VOL for which the capacity
is increasing.
20A2
The pair was not created because the S-VOL is an THP or Smart V-VOL for which capacity is increasing.
20A3
The pair task was rejected because FS is using the specified CG number.
20A9
The create pair task was rejected because the volume you specified as the P-VOL is an THP or Smart
V-VOL and its zero pages were being reclaimed.
20AA
The create pair task was rejected because the volume you specified as the S-VOL is an THP or Smart
V-VOL and its zero pages were being reclaimed.
20AB
The pair task was rejected because the volume you specified as the P-VOL is an THP or Smart V-VOL
and its capacity is increasing.
20B0
The pair task was rejected because the volume you specified as the S-VOL is an THP or Smart V-VOL
and its capacity is increasing.
20B1
The pair task was rejected because the volume you specified as the P-VOL is an THP or Smart V-VOL,
which is not associated with a pool.
20B4
The pair task was rejected because the volume you specified as the S-VOL is an THP or Smart V-VOL,
which is not associated with a pool.
20B5
The pair task was rejected because the emulation type of the volume you specified as the P-VOL is
3390-V.
20BD
The pair task was rejected because the emulation type of the volume you specified as the S-VOL is
3390-V.
20BE
The command was rejected because you were in the process of turning off the storage system’s power.
20C5
Locating and interpreting error codes and logs using the RAID Manager or BCM
81