Description

SSB2 code

The pairresync RAID Manager command was rejected because the volume you specified as the
S-VOL is the P-VOL of the splitting pair.

2358

The volume you specified as a P-VOL is a Cnt Ac-S Z P-VOL. The reverse resynchronization was rejected
because the Cnt Ac-S Z pair is not suspended (“Suspend/SUSPER” status) or split (“Split/SUSPOP”
status).

235B

The volume you specified as the P-VOL is a Cnt Ac-S Z S-VOL. The reverse resynchronization was
rejected because the Cnt Ac-S Z pair is not suspended (“Suspend/SUSPER” status) or split
(“Split/SUSPOP” status).

235C

The volume you specified as an S-VOL was a Cnt Ac-S Z P-VOL. The reverse resynchronization was
rejected because the Cnt Ac-S Z pair is not suspended (“Suspend/SUSPER” status) or split
(“Split/SUSPOP” status).

235D

The reverse resynchronization was rejected because the volume you specified as the P-VOL has the
S-VOL Disable attribute assigned by the Data Retention.

236C

The pair task was rejected because the volume you specified as the S-VOL has the S-VOL Disable
attribute assigned by the Data Retention.

236D

The pair task was rejected because the volume you specified as the P-VOL is not mounted.

2370

The pair task was rejected because the volume you specified as the P-VOL is blocked.

2371

The pair task was rejected because the volume you specified as the P-VOL is being formatted or
shredded.

2372

The pair task was rejected because the volume you specified as the P-VOL is a command device.

2373

The pair task was rejected because of one of the following reasons:

2380

The volume you specified as the S-VOL is not mounted.

The MU number is 3 or larger.

The pair task was rejected because the volume you specified as the S-VOL is blocked.

2381

The pair task was rejected because the volume you specified as the S-VOL is being formatted or
shredded.

2382

The pair task was rejected because the volume you specified as the S-VOL is a command device.

2383

The pair task was rejected because the volume you specified as the S-VOL is a reserved volume for
Auto LUN.

2386

The pair was not created because the volume you specified as the P-VOL is the volume for Auto LUN.

2387

The pair was not registered in the CG because the number of the pairs assigned to the CG has
exceeded the defined maximum number of pairs.

2394

The pair task was rejected because you are reverse resynchronizing the pair sharing the specified
volume as the P-VOL.

2395

The pair task was rejected because you are reverse resynchronizing the L1 pair sharing the specified
P-VOL as the root volume.

2396

The pair task was rejected because you are reverse resynchronizing the L2 pair sharing the specified
P-VOL or S-VOL as the node volume.

2397

The reverse resynchronization was rejected because the pair is not split (“Split/SUSPOP” status) or
suspended (“Suspend/SUSPER” status).

2398

The reverse resynchronization was rejected because some of the pairs sharing the specified volume
as the P-VOL are not in split (“Split/SUSPOP” status) or suspended (“Suspend/SUSPER” status).

2399

The pair was not created because you have set the Protect attribute for the volume you specified as
the P-VOL using BCM.

239D

The pair was not created because you set the Protect attribute for the volume you specified as the
S-VOL using BCM.

239E

Locating and interpreting error codes and logs using the RAID Manager or BCM