Hp-ux hosts, Hp-ux hosts -23, Table 1-6. drivers needed -23 – HP Surestore 6.140 Tape Library User Manual
Page 39
Getting Started
Configuring the Host System
Chapter 1
1-23
G
e
ttin
g
S
tar
te
d
2. Type “init 0” at any prompt. This will shut down all processes, and
take you to the OpenBoot PROM.
3. Type “reset”.
4. At the OK prompt, type “probe-scsi-all”.
Run a test backup to ensure that all components are properly configured.
HP-UX Hosts
To enable communication between the host and tape library, appropriate
drivers must be configured into the HP-UX kernel. Table 1-6 shows
which drivers are necessary for each device.
NOTE
Some drivers have different names, depending on whether or not they are
listed in the output of an ioscan or in the system file.
Table 1-6
Drivers Needed
Device
Driver Name
In ioscan
In system
file
SCSI Host Bus Adapter
(HSC or PCI Bus)
c720
c720
Fibre Channel Host Bus Adapter
fcp
fcT1_fcp
fcT1
fcT1
fcT1_cntl
fcT1_cntl
Fibre Channel Bridge or Multiplexer
fcpmux
fcpmux
Tape Library Robotics Controller
(HSC or PCI Bus)
sctl
sctl
Tape Driver (HSC or PCI Bus)
stape
stape
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)