Understanding Errors and Troubleshooting

Understanding Error States

Chapter 4

4-10

Drive critical
error

A critical error occurred on a
drive.

• Check the

Drive Event Log

from

the front panel or RMC Web-
Based Library Administrator
pages for possible causes.

• Contact your service

representative.

Drive not on Fibre
Channel

Drive(s) are detected by library
controller but are not detected
by any of the Fibre Channel
interfaces.

• Verify that this is your

intended configuration.

• Verify that there are no broken

or bent pins on the SCSI cables.

• Tighten all SCSI cables and

power cycle the library.

• If problem persists, replace the

SCSI cables.

• Contact your service

representative.

Firmware update
needed

A library component has
firmware that is different from
the rest of the library.

• Update library firmware.

(See page 4-60.)

Library fan
failure

A library card cage fan has
failed.

• Power cycle the library.

• Contact your service

representative.

Magazines
missing

Library could not detect all the
magazines.

• Ensure that all magazines are

present and correctly installed.
(See “Removing/Replacing a
Magazine” on page 2-12.)

Door open

One or more tape doors are
open. The library robotics will
not move until the door is closed.

• Ensure that doors are closed.

Table 4-1

Partial Availability Conditions

Library Status

Cause

Solution