HP Surestore 6.140 Tape Library User Manual
Page 116

Understanding Errors and Troubleshooting
Understanding Error States
Chapter 4
4-10
Drive critical
error
A critical error occurred on a
drive.
• Check the
Drive Event Log
from
the front panel or RMC Web-
Based Library Administrator
pages for possible causes.
• Contact your service
representative.
Drive not on Fibre
Channel
Drive(s) are detected by library
controller but are not detected
by any of the Fibre Channel
interfaces.
• Verify that this is your
intended configuration.
• Verify that there are no broken
or bent pins on the SCSI cables.
• Tighten all SCSI cables and
power cycle the library.
• If problem persists, replace the
SCSI cables.
• Contact your service
representative.
Firmware update
needed
A library component has
firmware that is different from
the rest of the library.
• Update library firmware.
(See page 4-60.)
Library fan
failure
A library card cage fan has
failed.
• Power cycle the library.
• Contact your service
representative.
Magazines
missing
Library could not detect all the
magazines.
• Ensure that all magazines are
present and correctly installed.
(See “Removing/Replacing a
Magazine” on page 2-12.)
Door open
One or more tape doors are
open. The library robotics will
not move until the door is closed.
• Ensure that doors are closed.
Table 4-1
Partial Availability Conditions
Library Status
Cause
Solution