beautypg.com

HP Surestore 6.140 Tape Library User Manual

Page 118

background image

Understanding Errors and Troubleshooting

Understanding Error States

Chapter 4

4-12

Fibre Channel
interface failed

Fibre Channel interface failed
power-up test. (Usually due to
problems on the SCSI bus, such
as an LVDS drive or terminator
on an HVDS bus, etc.)

• Verify that proper SCSI

terminators and/or tape drives
are attached to the Fibre
Channel interface, and then
reboot the library.

• Power cycle the library.

• Contact your service

representative.

Power supply
fault

Library detected one or more
redundant power supplies in a
failed condition.

• Determine which power supply

has failed. See page 4-27 for
LED status information.

• Contact your service

representative to replace the
power supply.

Table 4-1

Partial Availability Conditions

Library Status

Cause

Solution