beautypg.com

HP Surestore 6.140 Tape Library User Manual

Page 138

background image

Understanding Errors and Troubleshooting

Troubleshooting Common Problems

Chapter 4

4-32

Cannot navigate through
the RMC Web-Based
Library Administrator
interface.

• Do not use the

[Back]

or

[Forward]

buttons on the browser

to navigate. Instead, use the tabs and buttons on the
actual interface page.

Library Performance

HP-UX host responds
slowly or crashes after
connecting to the library.

• Check the SCSI IDs of all devices on the host buses to

ensure there are no conflicts on the bus.

• Check that the backup software does not require SCSI

IDs to be in a certain order.

• Contact your service representative.

The library is not
efficiently backing up data.

• Check the network bandwidth from the host computer.

• Check that the library’s drive(s) are on their own SCSI

bus and not daisy-chained to another tape drive or the
hard drive.

• Ensure that the drive is clean. See page 2-15 for more

information on cleaning the drive.

• Try a new tape. A marginal tape can cause performance

problems due to bad spots on the tape requiring retries.

• Ensure that the backup software is using fixed-length

records (or blocks) to maximize throughput and has not
defaulted to a smaller record size.

• Ensure that the data is being compressed.

• Check the size of the files. Small file size can impact

performance.

Operations

Cannot remember the
administration menu
password.

• Contact your service representative.

Table 4-12

Troubleshooting Table

Problem

Solution